GTalarm3 User manual V-2022-05-24
33 |
E N
Go to Sea2> System Options> Digital I/O settings
Set Digital I/O D2 to “Wiegand Interface DATA0”
Set Digital I/O D3 to “Wiegand Interface DATA1”
Press “Write”
Go to Sera2> System Options> General system Options.
Press "Start iButton/ RFID/ Phone programming mode.
Go to Sera2> Users/ Access control window.
Touch RFID keycards to the reader.
RFID keycard number will appear in the list.
Go to System Options> General system Options and
Press "Stop programming" or wait until it will stop automatically.
Edit setting in the Users/ Access control window.
Press "Write"
Go to RT Testing & Monitoring> Hardware.
Press "Start Monitoring"
Go to RT Testing & Monitoring> Security Alarm Panel/ Access
Start automatic learning mode via SMS command INST000000 063 1
Send SMS message: INST000000 063 1
You will receive the message: iButton/RFID/Caller ID
Learning Mode is Swithed ON
Touch RFID keycards to the RFID reader.
Sent the message: INST000000 063 0
You will receive the message: iButton/RFID/Caller ID
Learning Mode Stopped
INST000000˽063˽S
INST = Install. Configuration of the parameters.
000000= Installer‘s password
˽= Space character
063= command code (iButton keys learning/deleting mode)
˽= Space character
S=iButton keys entering/deletion mode.
0-
Disable iButton keys learning mode,
1-
Enable iButton keys learning mode,
2-
iButton keys deleting mode,
Delete these keys from memory, which will be touched to the
reader.
Before activating the RFID learning mode via SMS, the module
must have the appropriate System Options> Digital I/O Settings
-
For Wiegand keypad: “Wiegand interface DATA0 and Wiegand
interface DATA1 must be set.
- For iButton probe Dallas 1-Wire Bus must be set
Enter Keycard numbers manually via mini USB cable (Sera2 software).
Go to Sea2> System Options> Digital I/O settings
Set Digital I/O D2 to “Wiegand Interface DATA0”
Set Digital I/O D3 to “Wiegand Interface DATA1”
Press
“Write”
Go to Sera2> Users/ Access control.
Enter RFID keycard number
Edit other settings
Press "Write"
Go to RT Testing & Monitoring> Hardware
Press "Start Monitoring"
Go to Security Alarm Panel/ Access"
Touch the keycard to the RFID keypad.
Start automatic learning mode remotely via Sera2 software.