GTalarm3 User manual V-2022-05-24
22 |
E N
The module has 2 I/O analogue input/ output circuits I/O1 and I/O2. They also can be used for burglary alarm zones. Input type: NC/NO/EOL/
EOL+TAMPER. I/O1, I/O2 do not have internal pull-up resistors unlike IN1-IN4. So if you want to use I/O as burglar zones to connect NO/NC/EOL sensors
to I/O1 or I/O2 you have to connect external 5.1K resistor between I/O and +VD, as is shown in attached diagram.
I/O1, I/O2 do not have internal pull-up resistors. So if you want to connect NO/NC sensors to I/O1 or I/O2 you have to connect 5.1K
resistor between I/O and +VD
Please note. If I/O1 set as 2-wire, you don't need 5.1k resistor.
Figure 23Burglar Alarm Zones settings
If you want to edit existing configuration
,
You have to read it (press “Read” in the command line)
Edit settings
Write
edited configuration (press “Write” in the command line)