19
2. Single/Dual Gate Set
Press and hold the
“FUNC” button for more than 4 seconds. The Digital
Display will indicate
“
P1
”. Gate opener is on the SINGLE/DUAL Gate
setting. Press the
“INC” and “DEC” buttons respectively to following
modes:
“01” shown in Digital Display, it is Single Actuator 1 (Gate 1) mode. “10”
shown in Digital Display, it is Single Actuator 2 (Gate 2) mode.
“11”
shown in Digital Display, it is Dual actuator mode.
Press the
“FUNC” button to store the data when the single or dual gate
is chosen. The Digital Display will indicate
“P2”. Now single/dual gate
set is finished.
(Factory set is
“11”)
NOTE:
Every step for pressing button during program must be finished within 1 second to ensure successful
programming.
Setting of the Control Board
WARNING: Ensure the gate opener is Power Off when you make any adjustment of the gate opener.
Keep away from the path of the gate during you set the gate opener system in case of the unexpected
gate moving. Carefully adjust settings to avoid the risk of machine damage and injury or death. Always
ask the help of professional technician /electrician if you have any question.
1.
Check again for completed and correct assembly of your swing gate opener and gate. Plug the Power Cord
into the nearest AC outlet. The Digital Display on the Control Board will flash with
“- -”. The unit is in standby.
NOTE:
You can follow these steps to enter the setting menu, finish
all the setting program
, and then go back
to the stand-by state.
If you only need to adjust
one setting program
, press and hold “FUNC” button for more than 4 seconds. The
digital display will indicate “
P1
” , then press “FUNC” button repeatedly to get the
desired setting program of
―P?‖
, then press the “INC” and “DEC” buttons to adjust correspondingly. When the setting is finished, press the
“FUNC” button repeatedly to store the data, until the digital display on the control board flashes with “- -”, the
unit goes back to the standby state.
3. Master/Slave Gate Set
When Digital Display indicates
“P2”, the gate opener is on the Master/Slave Gate Setting. Press the “INC” and
“DEC” Buttons respectively to follow modes:
“01” shown in Digital Display, which means Gate Opener 1 (right-hand side) as Master one
“10” shown in Digital Display, which means Gate Opener 2 (left-hand side) as Master one
Содержание KD902
Страница 6: ...3 KD902 Parts List Accessories Parts Included in some models refers to the actual package...
Страница 18: ...15 Connecting of the Control Board...
Страница 28: ...25 Quick Setting Guide...
Страница 29: ...26...
Страница 30: ...27...
Страница 31: ...28...