background image

 

Safety Installation Information 

1.  READ and FOLLOW all instruction. 
2.  The gate opener is intended for use with Class I vehicular 
swing gates. 
Class I denotes a vehicular gate opener (or system) dwellings, 
or a garage or parking area associated therewith. 
Install the gate opener only when the opener is appropriate for 
the construction and the usage class of the gate. 
3.  Gate opening system designers, installers and users must 
take into account the possible hazards associated with each 
individual application. Improperly designed, installed or 
maintained systems can create risks for the user as well as the 
bystander. Gate system design and installation must reduce 
public exposure to potential hazards. All exposed pinch points 
must be eliminated or guarded. 
4.  A gate opener can create high levels of force during 
normal operation. Therefore, safety features must be 
incorporated into every installation. Specific safety features 
include safety sensors. 
5.  The gate must be properly installed and work freely in 
both directions prior to the installation of the gate opener. 
6.  The gate must be installed in a location so that enough 
clearance is provided between the gate and adjacent structure 
when opening and closing to reduce the risk of entrapment. 
Swinging gates shall not open into public access areas. 
7.  The opener is intended for use only on gates used for 
vehicles. Pedestrians must be supplied with a separate access 
opening. The pedestrian access opening shall be designed to 
promote pedestrian usage. The pedestrian access shall be 
located such that persons will not come in contact with the 
moving vehicular gate.

 

 

 

8.  Pedestrians should never cross the pathway of a moving 
gate. The gate opener is not acceptable for use on any 
pedestrian gate. Pedestrians must be supplied with a separate 
pedestrian access. 
9.  For an installation utilizing non-contact sensors (safety 
sensors), see product manual on the placement of non-contact 
sensors (safety sensors) for each type of application. 

a.  Care shall be exercised to reduce the risk of nuisance 
tripping, such as when a vehicle trips the safety sensor while 
the gate is still moving. 
b.  One or more non-contact sensors (safety sensors) shall 
be located where the risk of entrapment of obstruction exists, 
such as the perimeter reachable by a moving gate or barrier. 
10.  Never  mount any device that operates the gate opener 
where the user can  reach over, under, around or through the 
gate to operate the controls. Controls are to be placed at least 6’ 
(1.8m) from any part of the moving gate. 

 

11.  Controls intended to be used to reset an operator after 2 
sequential activations of the entrapment protection device or 
devices must be located in the line of sight of the gate, or easily 
accessible controls shall have a security feature to prevent 
unauthorized use. Never allow anyone to hang on or ride the 
gate during the entire travel of the gate. 
12.  Each gate opener is provided with two safety warning 
placards. The placards are to be installed on the front and back 
of the gate where they are plainly visible. The placards may be 
mounted using cable ties through the four holes provided on 
each placard. 
All warning signs and placards must be installed where visible 
in the area of the gate.

   

 

13. To AVOID damaging gas, power, or other underground 
utility lines, contact underground  utility locating companies 
BEFORE digging. 

14.

  Do not permit children to play on or around the gate and 

keep all controls out of their reach. 
15. SAVE INSTRUCTION. 

Содержание Casar MT8012

Страница 1: ...ens com MT8012 VER 21a C030564 Please read and follow all warnings precautions and instructions before installation and use Never connect the solar panel to the control board directly to charge the ba...

Страница 2: ...k Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street Address Apartment Unit City State Province Zip Code Country Region Approximate Ga...

Страница 3: ...ion 7 Install the Opener on the Gate for Pull to Open 7 Install the Opener on the Gate for Push to Open 10 Mounting the Control Box 13 Connection of the Power Supply 14 Connecting of the Control Board...

Страница 4: ...ould never cross the pathway of a moving gate The gate opener is not acceptable for use on any pedestrian gate Pedestrians must be supplied with a separate pedestrian access 9 For an installation util...

Страница 5: ...eway gates made by steel wood vinyl and shaped as panel tube and chain link While use on solid surface gates is NOT recommended Solid surface gates have a high resistance to the wind If the wind is st...

Страница 6: ...3 MT8012 Parts List Accessories Parts Included in some models refers to the actual package JD24VY 24V Warning Light TC102 Photo Eye Beam Sensor 25FT Extension 5 Conductor Cable...

Страница 7: ...it Wand HLR01 HomeLink Remote Control Kit TC173 Wireless Push Button TC147 Wired Push Button ET24 Electric Gate Lock TRF3 Reflection Photocell Sensor TC102 Photo Eye Beam Sensor JD24VY 24V Warning Lig...

Страница 8: ...Travel 380mm 15 in Ambient Temperature 20 50 4 F to 122 F Protection Class IP44 NOTE NR indicates this size and weight combination is NOT recommended for one arm actuator NOTE Ball bearing hinges shou...

Страница 9: ...g Reverse in case of obstruction during gate closing Built in adjustable auto close 0 99 seconds Built in max Motor running time MRT adjustable for multiple safety protection 1 50 seconds Digital disp...

Страница 10: ...bles are required to determine the proper mounting position for the Post Bracket The tables show the maximum opening angle of the gate for a given A and B For example if A is 18cm and B is 16cm the ma...

Страница 11: ...with the Post Bracket Assy and Gate Bracket on the gate post and the gate While holding the gate opener in the level position temporarily secure it with two C clamps 5 Make sure that there is a minimu...

Страница 12: ...ions 8 Attach the post bracket assemblies to the gate posts by using four expansion bolts 9 Attach the gate brackets to each gate by inserting two M8x80 bolts through the gate brackets and the drilled...

Страница 13: ...ortant The following illustrations and tables are required to determine the proper mounting position for the Post Bracket The tables show the maximum opening angle of the gate for a given A and B For...

Страница 14: ...for Push to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gate post and the gate While holding the gate opener in the level position temporarily secure it with...

Страница 15: ...semblies and the gate bracket It allows slight adjustments to the post bracket Then remove the post bracket and gate bracket by taking off the C clamps 7 Drill 14mm diameter holes on the gate post and...

Страница 16: ...is restores normal operation NOTE The setting of the PULL PUSH TO OPEN of the control board should be in accordance with the installation Mounting the Control Box Step 1 To install the control box use...

Страница 17: ...t other cables into the control box through rightmost strain relief Then repeat step 2 NOTE Only motor cables 1 5m length are provided Other cables are subject to site installation requirement and not...

Страница 18: ...15 Connecting of the Control Board...

Страница 19: ...e is no solar panel to be used for charging the battery then the 24V of the battery should be wired to the BAT 13 terminal 24V should be wired to BAT 14 terminal The battery could also be charged by t...

Страница 20: ...OWN wire of the external receiver should be connected into the 19 terminal The BLACK wire of the external receiver should be connected into the 20 terminal The RED wire of the external receiver should...

Страница 21: ...e to only operate TOPENS swing gate opener A B C and D four buttons share same function once they are programmed with TOPENS swing gate opener You may choose any button to program it with our swing ga...

Страница 22: ...ensure successful programming Setting of the Control Board WARNING Ensure the gate opener is Power Off when you make any adjustment of the gate opener Keep away from the path of the gate during you se...

Страница 23: ...tween Master Slave Gate Setting The open interval can be adjusted by pressing the INC and DEC Buttons respectively The Digital Display will show 0 9 which indicates the interval time 0 means the Maste...

Страница 24: ...MOTOR1 is adjusted by pressing INC and DEC buttons respectively The Digital Display will show 01 50 which indicates the MRT of MOTOR1 from 1 to 50 seconds You can hold pressing the INC or DEC button...

Страница 25: ...eriod STP is set at 3 sec and the GRP is 23 sec you can calculate the GRP period by yourself from the arm actuator starting to move on the fully open position to the arm arriving at the fully close po...

Страница 26: ...y a silicone spray to reduce its friction In cold climates where temperatures reach 1 C 30 F or less spray silicone on the actuator every 4 6 weeks to prevent freeze up 2 Regularly check gate hinges t...

Страница 27: ...n cold weather as the gate will not move freely 3 Check if the MRT period is too short Gate opens but does not close 1 Photocell PBS function is enabled in control board setting but is not equipped op...

Страница 28: ...25 Quick Setting Guide...

Страница 29: ...26...

Страница 30: ...27...

Страница 31: ...28...

Страница 32: ...any need to contact us the info below will help you get in touch TOPENS Website www topens com Contact Us E mail support topens com Kindly include your Product Model Purchasing Date Site Order and yo...

Отзывы: