18
COMPONENTS
PRINTER OUTPUT (IN REF/KRT MEASUREMENT MODE)
KRT typical value style and KRT print data are HV
NOTE
• The reliability factor is defined with integers 1 to 9 in increasing order of
reliability.
• Additionally, if the reliability is high enough, the reliability factor is not
shown on the printout.
• The Near PD value is calculated based on the ADD.
• ( ) appears when normal measurement is not expected due to eyelid,
eyelash, or blinking.
• *-mark appears when normal measurement is not expected with the
button selected.
NAME
REF. DATA
〈R
C9
C8
C7
〉
S
-0.25
-0.75
88
-0.25
-0.75
90
CYL : ( - )
C
A
VD : 13.75
2010̲ 12̲24 AM 10 : 00
N o . 0 0 0 1 01
-KR 010602-
-0.25
-0.75
90
S.E.
-0.25
S.E.
-0.75
-0.25
-0.75
90
〈L〉
S
+0.25
(
)
-0.75
88
+0.25
-0.75
90
C
A
+0.25
-0.75
90
+0.25
-0.75
-0.75
90
-0.25
+0.25
90
90
KRT.DATA
〈R〉
CORNEA DIA : 12.00
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
-1-
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
-2-
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
-3-
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
OID :
SN
:
TOPCON
〈L〉
CORNEA DIA : 12.00
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
-1-
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
-2-
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
-3-
D
H
43.50
7.77
1
43.25
7.79
43.25
7.80
91
V
CYL
-0.25
91
AVG
MM
A
PD : 65
ADD :2.25
NPD :61
Bar code
Work ID No.
Patient No. (Patient ID
when patient ID is input)
Device ID number
VD (vertex distance)
Cylinder sign
3 readings of REF right mea-
surement (recordable up to 10
measurements)
Typical value of right eye
SPHERICAL EQUIVALENT of
right eye
The ( ) mark is added when
measurement values are not
fully reliable.
Pupil distance (PD value) (mm)
Near vision PD value
ADD (standard additional power)
Operator ID
Serial number
Refractive power measurement result (R)
Refractive power measurement result (L)
3 readings of kerato-cylinder
value, average value and
kerato-cylinder value
(recordable up to 10 mea-
surements each for right/left
eye)
Left eye corneal curvature
measurement
Typical measured value of right eye corneal curvature
Measured value of horizontal
corneal curvature
Measured value of vertical
corneal curvature
Corneal astigmatic axis
angle
Measured value of right
eye cornea diameter
Typical measured value of
Left eye corneal curvature
Reliability
factor
C (Cataract
mode) mark
TOPCON logo mark
Cataract
Содержание TRK-2P
Страница 1: ...USER MANUAL AUTO KERATO REFRACTO TONOMETER TRK 2P...
Страница 2: ......
Страница 116: ......
Страница 118: ...AUTO KERATO REFRACTO TONOMETER TRK 2P 41852 97030 Printed in Japan 1311 100LW0...