![Topcon KR-1W Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/topcon/kr-1w/kr-1w_instruction-manual_1128648178.webp)
176
TERMINOLOGY
Term
Description
Page
Limit Message
Displayed with icon when measuring head reaches the
limit of movement. To clear the message, move measur-
ing head by control lever.
Luminous Point
Index for performing auto alignment.
Machine No.
Instrument No.
Marker Overlay
The angle of the tap position with regard to the flat merid-
ian (black) is displayed. Also, the steep meridian is dis-
played in gray.
Measurement Data List
Button on the measurement screen of main body. In KR-
1W, Ref/Kerato measurement values are displayed in list
form.
Measurement Result List
screen
List of measurement results can be confirmed.
Mire Image
Image taken by CCD camera by projecting ring beam
from Placido ring to patient.
mm Grid scale
KR-1W can display grid on maps of measurement
results.
MTF Image
Short for Modulation Transfer Function, showing the con-
trast sensitivity of eye having aberration.
MTF Image Graph
Graph showing the sensitivity calculated by MTF along
vertical axis and the space frequency along horizontal
axis, and featuring curves' performance which increases
towards upper right and decreases towards lower left.
Multi Map (analysis result
display map)
Displays the analysis result obtained by Hartmann image
and Mire image.
Normalized
A type of color code scale of analysis result.
For KR-1W, three types of scales, absolute/adjustable/
normalized are available.
"Normalized" is a relative scale with automatically
selected color code center value and display step.
Ocular
Display related to eyeball.
Ocular HOA map
High order aberration of the ocular aberration obtained
from Hartmann image.
Ocular R-L Map (Analysis
Result Display Map)
The Ocular R-L map displays the Hartmann image, ocu-
lar high order aberration map, Landolt's simulation, mea-
surement values, etc. of both eyes.
Ocular Total Aberration
map
Aberration of the whole eyeball obtained from Hartmann
image.
Packing mode
Automatically returns movable parts of KR-1W (measur-
ing head and chinrest) to packing positions (measuring
head to origin position, chinrest to bottom position).
Patient ID button
Button to input patient ID.
Photopic
Means bright place measurement.
Содержание KR-1W
Страница 1: ...INSTRUCTION MANUAL WAVE FRONT ANALYZER KR 1W ...
Страница 2: ......
Страница 186: ......
Страница 188: ...KR 1W WAVE FRONT ANALYZER 41835 97992 Printed in Japan 2010 02 100LW2 ...