8-13
8 LAYOUT
5
Enter instrument height in the same way.
[F1]
Enter
INS.HT
[F4]
6
Enter the known point A number. *3)
[F1]
Enter PT#
[F4]
7
Enter reflector height.
[F1]
Enter R.HT
[F4]
8
Collimate the known point A, and press the
[F3](ANG) or [F4](DIST) key.
Example:[F4](DIST)
Distance measuring starts.
Known point B entering display will be shown.
Collimate A
[F4]
9
Same as procedure
6
to
8
proceed to the known
point B.
When two points have been measured by the
[F4](DIST) key, the RESIDUAL ERROR will be
calculated. *4)
10
Select GRID FACTOR for calculation of
RESIDUAL ERROR by pressing [F1] or [F2]
key. *5)
Example: [F1]
[F1]
11
Press the [F1](NEXT) key to measure other points.
Maximum seven points can be measured.
[F1]
12
Same as procedure
6
to
8
proceed to the known
point C.
NO01#
PT#:
INPUT LIST NEZ ENTER
REFLECTOR HEIGHT
INPUT
R.HT : 0.000 m
INPUT ––– ––– ENTER
REFLECTOR HEIGHT
INPUT
R.HT : 1.235 m
>Sight ? ANG DIST
HR: 123°40'20"
HD* < m
VD: m
> Measuring...
< complete >
NO02#
PT#:
INPUT LIST NEZ ENTER
SELECT GRID FACTOR
F1:USE LAST DATA
F2:CALC MEAS.DATA
RESIDUAL ERROR
dHD= 0.015 m
dZ = 0.005 m
NEXT ––– G.F CALC
NO03#
PT#:
INPUT LIST NEZ ENTER
HR: 123°40'20"
HD* < m
VD: m
> Measuring...
< complete >
HR: 123°40'20"
HD: 123.456 m
VD: 1.234 m
NEXT ––– ––– CALC
Содержание GTS-230 Series
Страница 1: ...ELECTRONIC TOTAL STATION GTS 230 SERIES GTS 233 GTS 235 GTS 236 INSTRUCTION MANUAL GTS 239...
Страница 2: ......
Страница 124: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 125: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 157: ...23 4 23 SPECIFICATIONS...
Страница 162: ......