4-13
4 DISTANCE MEASUREMENT
After the measurement, angle measuring display
of the left side (P2) will be shown.
6
Collimate the left side of the column (P2) and
press the [F4](SET) key.
After the measurement, angle measuring display
of the right side (P3) will be shown.
Collimate
P2
[F4]
7
Collimate the right side of the column (P3) and
press the [F4](SET) key.
The distance between the instrument and center
of the column (P0) will be calculated.
Collimate
P3
[F4]
8
To show the relative elevation (VD), press the
[
] key.
Each time pressing the [
] key, horizontal
distance, relative elevation and slope distance are
shown in sequence.
[
]
●
To show coordinate of point P0, press the [
]
key.
9
To escape the measuring, press the [ESC] key.
The display returns to the previous mode.
COLUMN OFFSET
Left
HR: 120°30'40"
--- --- --- SET
COLUMN OFFSET
Right
HR: 180°30'40"
--- --- --- SET
COLUMN OFFSET
HR: 150°30'40"
HD: 43.321 m
NEXT --- --- ---
COLUMN OFFSET
HR: 150°30'40"
VD: 2.321 m
NEXT --- --- ---