Sensor Filtering
4-6
P/N: 7010-1006
Calibration
5. Tap
Next
.
6. With the
Bucket Pivot Point
and the
Bucket Teeth
aligned at zero (0.0) degrees, tap
Next
(Figure 4-7).
Figure 4-7: Calibrate Attachment Angle
7. Set the bottom of the
Bucket
flat on the ground and press
Finish
(Figure 4-8).
Figure 4-8: Calibrate Bucket Base
Sensor Filtering
The filter level for
each
sensor can be changed depending on the application and the operator’s
choice. A value of 4 (heavy filtering) will dampen sensor reaction, while a value of 1 (light filtering)
will cause faster sensor reaction.
1. Using the 3D-MC Software Interface, tap
Topcon Menu Button
>
Control
>
Machine
>
Setup
. Select the applicable machine file and tap
Edit
.
2. Tap
Next
to navigate to the
Loader Frame/Sensors
screen (Figure 4-9).
3. Tap the
Wrench
Icon
next to the Sensor ID that you will be adjusting.