Boom Sensor Calibration
4-3
P/N: 7010-1006
Calibration
Boom Sensor Calibration
1. Tap the
Wrench Icon
that corresponds to the
Boom
sensor (Figure 4-3).
2. Select the correct
Orientation
from the drop-down menu.
3. Ensure the Wheel Loader is parked on a flat and stable surface.
4. Place a zero slope rotating laser along the side of the Wheel Loader.
5. Adjust the laser height to strike the center of the Boom Pivot.
6. Move the
Boom
to align the Bucket Pivot with the laser.
7. Tap the
Wrench Icon
that corresponds to the
Boom
sensor.
Figure 4-3: Boom Sensor Calibration Screens
8. Tap
Set
next to
Pitch
on the
Sensor Calibration
screen, enter the value as zero, and tap
Set
again (Figure 4-3).
9. Tap
Ok
to return to the
Loader Frame/Sensors
screen.
When performing the
Boom Sensor Calibration
, a laser is recommended to
correctly position the Boom to zero degrees.
The laser should shine on both the Boom and Bucket Pivots.