4.3 GENERAL SAFETY
INSTRUCTIONS
• Never leave children alone or unat-
tended at a burning fireplace.
• Teach your children how to behave
properly and operate safely the fire-
place.
• Every stove gets hot when fired: risk
of burning!
• Avoid touching the outside surfaces
when the stove is operating.
• Do not burn refuse or painted wood.
• Dispose of the ashes only after they
have cooled completely.
• Inform your specialised dealer wit-
hout delay of defect gaskets.
• Observe the information in our
operating instructions and make a
proactive contribution to fire pre-
vention and the protection of our
environment.
4.4 CHIMNEY SAFETY
INSTRUCTIONS
The condition and functionality of
your chimneys must be inspected by
a chimney sweep or specialist before
the Tonwerk storage heating stove is
installed.
This will provide the optimal condi-
tions for trouble-free heating.
4.5 CONDUCT DURING
MALFUNCTIONS –
SHUTTING DOWN
SAFELY
In rare cases, also a pilot fire can fail to
generate a draught in the flue.
You must then ask your chimney
sweep for advice. On no account must
you attempt to light a larger fire. When
smoke escapes from your stove, air
the room immediately and contact
your chimney sweep. You should then
refrain from firing your stove.
4.2 SAFETY DISTANCES TO SWIVELLING TONWERK STORAGE
HEATING STOVES: T-LOFT, TOPOLINO
Safety distance A
The side and rear panels must be no closer
than 10 cm to flammable materials
Safety distance B
Smoke pipes must be no closer than
20 cm to flammable materials
Safety distance C+D
The distance over the whole swivelling
angle must be no less than 50 cm
Safety distance E
A minimum distance of 80 cm applies to
the whole swivelling range
Safety distance F
The minimum distance from the ceiling
is 50 cm
Safety distance A
The side and rear panels must be no closer
than 10 cm to flammable materials
Safety distance B
Smoke pipes must be no closer than
20 cm to flammable materials
Safety distance C + D
Flammable floor materials must be
no closer than 50 cm to the front and
30 cm to the sides
Safety distance E
Firing chamber apertures must be no
closer than 80 cm to flammable mate-
rials within the radiation zone
Safety distance F
The minimum distance from the ceiling
is 50 cm
4.1 SAFETY DISTANCES TO FIXED TONWERK STORAGE
HEATING STOVES: T-LOFT, TOPOLINO
4. FIRE PROTECTION
The national and European standards, the local and building legislation, and the
fire safety terms and conditions must be observed without condition.
Your chimney sweep or Tonwerk partner company will be pleased to inform you.
C + D
A
A
D
D
C
E
E
A
A
A
A
B
B
F
F