Tong Yi Fang Glass Machinery co.,ltd.                           

   

                                                       

 

- 5 -

 / 

7

 

 

and you also need to change the new water according to the cleanliness.   

3.9 Please keep the transmission roller clean and dry. 

IV. Notice 

4.1  After  turning  off  the  heating,  please  keep  the  blower  work  for  3-5 

minutes,  to  prevent  distortion  on  the  rubber  transmission  rollers.  Then 

you can turn off the blower after the heating wires in the heating box get 

cooled. 

4.2  The  heating  section  has  self-locking  function,  only  after  starting  the 

blower, the heating switch can be gone electricity. 

4.3  Scratches  on  the  surface  of  the  sponge  rollers,  will  affect  their 

absorption  capacity.  Their  normal  using  life  is  3-6  months,  you  would 

better to change them after this duration. 

4.4  Sponge  rollers  should  be  maintained  into  water  without  pressure,  to 

prevent from distortion.   

      If  you  need  to  turn  off  the  machine  for  long  time,  please  lift  the 

sponge rollers, from preventing pressure and distortion, which will affect 

the absorption capacity. 

4.5  When  the  machine  is  working  and  emergent  stop  is  needed,  please 

press the emergent stop button. 

 