AL-2000 Biometer & Pachymeter
63
7
7..3
3 U
Uttiilliittyy S
Se
ettu
up
p ffo
orr B
Biio
om
me
ettrryy &
& IIO
OL
L C
Ca
allccu
ulla
attiio
on
n
7
7..3
3..5
5 B
Biio
om
me
ettrryy//IIO
OL
L D
Da
atta
a M
Ma
an
na
ag
ge
em
me
en
ntt
•
• A
Asscce
errtta
aiin
n tth
ha
att tth
he
e m
me
em
mo
orryy cca
arrd
d iiss sse
eccu
urre
ellyy iin
nsse
errtte
ed
d a
ass iin
nssttrru
ucctte
ed
d iin
n
sse
eccttiio
on
n 3
3..2
2..2
2ff..
•
• T
Th
he
e m
me
em
mo
orryy cca
arrd
d m
mu
usstt b
be
e ffo
orrm
ma
atttte
ed
d b
be
effo
orre
e u
ussiin
ng
g,, a
ass d
de
essccrriib
be
ed
d iin
n
sse
eccttiio
on
n 8
8..4
4..
IOL data stored on the memory card (as
described in section 7.3.4b) may be analyzed to
display four types of graphs, illustrated in figs. 2-
5. The patient data are compiled according to
IOL Model name. If two or more IOLs bear the
same name, they will be treated as the same lens
even if they have different lens constants.
1. Insert the memory card as instructed in section
3.2.2f.
2. Touch the D
Da
atta
a M
Ma
an
na
ag
ge
em
me
en
ntt key (1) on the
biometry Utility screen (fig. 1) to display the
Graph screen (figs. 2-5).
3. The following four graphs may be displayed by
touching the corresponding G
Grra
ap
ph
h key (2):
G
Grra
ap
ph
h 1
1: Relationship between axial length
and personal lens constant (fig. 2).
G
Grra
ap
ph
h 2
2: Relationship between anterior cham-
ber depth and personal lens constant
(fig. 3).
G
Grra
ap
ph
h 3
3: Relationship between IOL power and
personal lens constant (fig. 4, next
page).
G
Grra
ap
ph
h 4
4: Histogram showing personal lens
constant values (fig. 5, next page).
The following values for the lens constant asso-
ciated with the selected formula and lens
model are displayed at the left of the screen:
mean value, maximum value, minimum value
and standard deviation. The number of data
points is also displayed.
4. Touch the F
Fo
orrm
mu
ulla
a key (3) to change the calcu-
lation formula for which data are displayed.
5. Touch the M
Mo
od
de
ell key (4) to change the IOL
model for which data are displayed.
6. Touch the E
Ex
xiitt key (5) to return to the biometry
Utility screen.
Содержание AL-2000
Страница 9: ...AL 2000 Biometer Pachymeter...
Страница 13: ...AL 2000 Biometer Pachymeter 4...
Страница 41: ...AL 2000 Biometer Pachymeter 32 4 4 3 3 I IO OL L P Po ow we er r C Ca al lc cu ul la at ti io on n...
Страница 89: ...AL 2000 Biometer Pachymeter 80 8 8 M Me em mo or ry y C Ca ar rd d...
Страница 111: ...AL 2000 Biometer Pachymeter...
Страница 118: ...AL 2000 Biometer Pachymeter 109...
Страница 119: ......