![Tomey AL-2000 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/tomey/al-2000/al-2000_operators-manual_1125660045.webp)
AL-2000 Biometer & Pachymeter
36
5
5..1
1 P
Pa
acch
hyym
me
ettrryy M
Mo
od
de
e S
Se
ettu
up
p
5
5..1
1..3
3 S
Se
ettttiin
ng
g tth
he
e M
Me
ea
assu
urre
em
me
en
ntt C
Co
on
nd
diittiio
on
nss
Before measuring corneal thickness, the following measurement conditions should
be set:
• Patient name, patient ID and physcian name
• Eye (right/left)
• Converted velocity and bias mode
• Acquisition mode
• Measurement mode
• Measurement range
• Measurement display
• Data presentation mode
a
a)) P
Pa
attiie
en
ntt n
na
am
me
e,, p
pa
attiie
en
ntt IID
D n
nu
um
mb
be
err a
an
nd
d p
ph
hyyssiicciia
an
n n
na
am
me
e
b
b)) S
Se
ettttiin
ng
g tth
he
e e
eyye
e tto
o b
be
e m
me
ea
assu
urre
ed
d
S
Stto
orre
ed
d d
da
atta
a a
arre
e cco
on
nttrro
olllle
ed
d b
byy IID
D n
nu
um
mb
be
errss.. IIff yyo
ou
u p
plla
an
n tto
o sstto
orre
e
d
da
atta
a o
on
n tth
he
e m
me
em
mo
orryy cca
arrd
d,, yyo
ou
u m
mu
usstt e
en
ntte
err a
a p
pa
attiie
en
ntt IID
D n
nu
um
mb
be
err..
Up to 10 letters can be entered for each
item.
1. Touch the IIn
nd
de
ex
x key (1) on the measure-
ment window (fig. 1) to display the
Name/ID entry window (fig. 2).
2. Touch the number keys and the alphabet-
ic character keys (2) to enter the patient’s
name, ID number and physician’s name.
If the physician’s name is already regis-
tered in the Physician List, it can be
selected by pressing the corresponding
number (6).
To switch between letters and numbers,
use the switch-over key (3). In the event
of an erroneous entry, touch the D
De
elle
ette
e
key (4).
3. To set the entered value and advance to
the next entry, touch the R
Re
ettu
urrn
n key (5).
The cursor location indicates the catego-
ry of the next entry.
4. Touch the IIn
nd
de
ex
x key (1) again to return to
the measurement window (fig. 1).
Touch the E
Eyye
e key (1) to select the eye you
wish to measure (right or left).
The right eye (OD) or the left eye (OS) is
selected alternately each time the E
Eyye
e key
is touched.
Содержание AL-2000
Страница 9: ...AL 2000 Biometer Pachymeter...
Страница 13: ...AL 2000 Biometer Pachymeter 4...
Страница 41: ...AL 2000 Biometer Pachymeter 32 4 4 3 3 I IO OL L P Po ow we er r C Ca al lc cu ul la at ti io on n...
Страница 89: ...AL 2000 Biometer Pachymeter 80 8 8 M Me em mo or ry y C Ca ar rd d...
Страница 111: ...AL 2000 Biometer Pachymeter...
Страница 118: ...AL 2000 Biometer Pachymeter 109...
Страница 119: ......