                Before Starting the Generator Engine

Before starting the engine: 
     a. Follow the Set Up Instructions to prepare the Generator. 
     b. Unplug all loads from the Generator. 
     c. Inspect the Generator and engine. 
     d. Fill the engine with the proper amount and type of both stabilizer-treated fuel and oil.
Basic Generator Use Procedure - See following pages for specific instructions
1. Check that the Generator can handle the wattage needed to power your products. 
2. Start the Engine, and allow the Engine and Generator to run and warm up for five minutes after 
starting with no electrical load. 
3. With the engine running, test GFCI receptacles before each use as follows: 
     a. Press Test button on receptacle to trip the GFCI device. 
     b. The Reset button should extend, cutting off electricity to the receptacle. 
     c. If above test fails, do not use receptacle until it is repaired or replaced. 
     d. Press Reset button in for use.
4. Plug in products. 
5. When finished using the Generator, disconnect all electrical loads. 

Note: 

Do not allow Generator to run out of fuel with loads attached. 

6. Turn off the Engine. 
7. Allow the Generator and its Engine to completely cool. Then store the unit in a clean, dry, safe 
location out of reach of children and other unauthorized people. 

IMPORTANT: 

After starting the engine, allow it to run at no load for five minutes with no load after each 

start-up so that the engine can stabilize. 
8. Break-in Period: 
     a. Breaking-in the engine will help to ensure proper equipment and engine operation. 
     b. The operational break-in period will last about 3 hours of use. During this period:
          • Do not apply a heavy load to the equipment. 
     c. The maintenance break-in period will last about 20 hours of use. After this period:
          • Change the engine oil. 

Using the Generator

SETUP

10

Содержание 79991

Страница 1: ...GASOLINE GENERATOR INSTRUCTION MANUAL SAVE THIS MANUAL You will need this manual for safety instructions operating procedures and warranty Put it and the original sales receipt in a safe dry place for...

Страница 2: ...Connections for standby power to a building electrical system must be made by a qualified electrician The connection must isolate the Generator power from utility power and must comply with all applic...

Страница 3: ...r Check that the startup surge will not be beyond the limit of the Generator Power levels between rated and maximum may be used for no more than 30 minutes 13 Avoid substantially overloading which wil...

Страница 4: ...Dress properly Do not wear loose clothing or jewelry Keep hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts 32 Parts especially exhaust...

Страница 5: ...ve the equipment serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the equipment is maintained Do not attempt any service or maintenance...

Страница 6: ...Running Watts 5000 Maximum Starting Watts 2x VDE PLUG Earthing 1x 12V DC Connection terminal Displacement 420cc Engine Type Horizontal Single Cylinder 4 stroke OHV Cooling System Forced air cooled Fue...

Страница 7: ...e load it protects are marked near the breaker Should any of the Circuit Breakers trip the Generator will stop the electricity output If this happens unplug all loads from the Generator Allow the Gene...

Страница 8: ...3mm grounding wire not included from the Grounding Terminal on the Control Panel to a grounding rod not included that has been driven at least 24 inches deep into the earth The grounding rod must be...

Страница 9: ...If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use 6 Thread the dipstick back in cloc...

Страница 10: ...receptacle c If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use 4 Plug in products 5 When finished using the Generator disconnect all electrica...

Страница 11: ...er Handle snap back against the engine Hold it as it recoils so it doesn t hit the engine If the engine is electrically started please follow step 1 2 3 and then turn the start knob to START Release t...

Страница 12: ...e capacity to the appliance tool or equipment Do not charge batteries without a proper charge controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive l...

Страница 13: ...ructions Cleaning Maintenance and Lubrication OPERATING INSTRUCTIONS 13 Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually...

Страница 14: ...ons for use 4 Replace the Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air CAUT...

Страница 15: ...t spark plug cap from end of plug Clean out debris from around spark plug 2 Using a spark plug wrench remove the spark plug 3 Inspect the spark plug If the electrode is oily clean it using a clean dry...

Страница 16: ...ted area out of reach of children Storage area should also be away from ignition sources such as water heaters clothes dryers and furnaces NOTICE During extended storage periods the Engine must be sta...

Страница 17: ...Pour tablespoon of oil into spark plug hole Crank engine a few times and try to start again 2 Tighten spark plug If that does not work replace spark plug If problem persists may have head gasket probl...

Страница 18: ...rt COMPRESSION RELATED section 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane...

Страница 19: ...ASSEMBLY DIAGRAM PARTS LIST ASSEMBLY DIAGRAM 19...

Страница 20: ...haft assy Weight balancer Clip piston pin Piston Pin piston Rod connecting 1 1 1 1 1 1 2 2 2 4 1 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 1 2 7 1 1 1 1 1 3 1 1 1 2 1 1 1 Ring the first Ring the second Ring s...

Страница 21: ...fixing lower Bolt Nut Wheel front Washer Pin frame assy engine black cushion engine frame Nut Nut Cushion engine frame rear Gasket fuel tank rubber Nut 2 1 2 1 1 4 4 4 4 1 1 1 1 1 2 1 1 1 1 1 2 1 1 3...

Страница 22: ......

Страница 23: ......

Страница 24: ...TOLSENisatrademarkor registeredtrademarkof TOLSEN TOOLS Allrightsreserved MADE IN CHINA TOLSEN TOOLS CO LIMITED www tolsentools com...

Отзывы: