STAC6 Drives and Microstepping Motors:
User Manual
(Discontinued Product)
• 1.26 •
1:
H A R D W A R E
The optional I/O expansion board adds four additional programmable
outputs. The outputs can be used to drive LEDs, relays and the inputs
of other electronic devices like PLCs and counters. The BRAKE,
ALARM and MOTION outputs can only
sink current.
The COM terminal must be tied to power supply (-).
Diagrams for each type of connection follow.
Do not connect the outputs to more than 30VDC. The current
through each output terminal must not exceed 100 mA.
Figure 1.28: STAC6 Outsinking
Figure 1.29: STAC6 Relay
!