STAC6 Drives and Microstepping Motors:
User Manual
(Discontinued Product)
• 1.25 •
1:
H A R D W A R E
Connecting Digital Outputs on the IN/OUT 1 Connector
Figure 1.26 Connections In/Out 1
The
S I
[STAC6-Si]
drives feature three digital outputs:
Brake:
Controls an electric brake relay, automatically releasing
and engaging as the drive requires.
Alarm:
Closes when a drive fault or alarm condition occurs. The
red and green LEDs will flash an error code.
Motion:
Indicates that the drive has achieved a desired goal, such
as a target position.
Figure 1.27: STAC6 Outputs