3-4
Tolomatic User Guide:
ICR Rod Style Integrated Control Actuator
3 :
I C R / I C M S V 1 P P L U S - E L E C T R I C A L I N T E R F A C E , S P E C S & W I R I N G
3.1.3 Optional Communications Cable
A communications cable is available as an option with the ICR/ICM SV1P Plus
actuator and can be used for daisy chaining a series of actuators together to a PLC,
PC, HMI, or other intelligent device.
CABLe
TOLOMATIC PART NO.
Communication Cable: 1 Meter
3604-1659
Communication Cable: 5 Meter
3604-1660
Figure 3-5: ICR/ICM SV1P Plus Optional Communications Cable
When cutting these cables for CANopen or DeviceNet connections, follow these
wiring guidelines.
Wiring for CANopen
Wiring for deviceNet
3 - Black, V- (CAN Ground)
1 - Drain, Shield
4 - White, CAN High
2 - Red, V+
5 - Blue, CAN Lo
3 - Black, V- (CAN Ground)
4 - White, CAN High
5 - Blue, CAN Lo
Ø .57
[ 14.5 ]
2.02
[ 51.3 ]
1.84
[ 46.7 ]
1M AND 5M LENGTHS
Ø .57
[ 14.5 ]
FEMALE
MALE
M12 X 1