6(16)
Under the dishwasher and sink or kitchen island with a sink:
One sensor on the plastic mat under the dishwasher, one sensor on the floor under
the sink, and one in the shaft where the pipes come up from the floor or in the
floor sill.
Under a fridge / freezer with water supply:
One sensor under the appliance which is to be monitored.
In the laundry room or bathroom:
In these areas, there is sometimes water splashing
during regular use; the floor must be waterproofed
and there must be a functioning floor drain. Place the
sensor (or sensors) where they will only touch water
in case of a leak resulting in rising water level, for
example in the threshold.
1.3 Daily Operation:
Monitoring of the water system takes place continuously and no daily measures
need to be taken. If external control is used, see section 1.6
If the central unit or remote unit is used to switch the water on and off daily, see
below.
Turn the water on
•
Press ON. Green light indicates that the water is on.
Turn the water off
•
Press OFF. Red light indicates that the water is off.
Delayed shutoff of the water
•
Press DELAYED OFF.
Red light indicates that the water will turn off after
a while.
•
The time until the water is switched off is set with the DIL switches, see
section 2.3. (Factory setting 2h) Pressing DELAYED OFF again reloads the