5(16)
1.2 The Different Parts:
The central unit:
The central unit controls the ball valves and monitors leaks in the water
distribution cabinet with the help of water sensors. It also receives
signals from the wireless devices.
Installed in a suitable place near the water distribution cabinet.
Motorised Ball Valves:
Motorised ball valves to turn water supply ON and OFF.
The units are intended for tap water, 0-60°C and 0-10 bar.
If the power goes out, they can also be operated manually
with a mechanical knob on the unit. Lift the knob 5 mm and
turn clockwise to close the valve. The indicator next to the
knob shows open/closed.
Fitted in the water distribution cabinet.
Water sensor:
The water sensor is placed in the water distribution cabinet
and when water is indicated, the control unit will switch off
incoming water.
Fitted in the water distribution cabinet.
Remote unit:
(optional)
From here you can easily turn the water off and on with a wireless signal to
the control unit.
Place by the front door.
Water detector:
(optional)
Each water detector comes with three sensors which are
positioned in suitable places. The water detector sends a radio
signal to the central unit and beeps with pulsing sound signals
when it detects water. The water detector sends an "I am alive"
signal every 24 hours to the central unit.
Below are several different installation suggestions: