background image

3

12 

2.    After  pushed    SET    switch

,  select  either  "GNSS"  or  "GYRO"  by  pushing 

 

or 

  switch

Every pushing of 

  or 

  switch

  caused blinking display of the following two 

kinds of data alternately as shown below. 

Input system:    GYRO 

 
 
 

Input system:    GNSS 

 
 
 

3.    Determine it by pushing    ACK/ENT    switch

 
4.    When "GYRO" was selected, as the latitude is displayed in the data indicator, set 

the  latitude  by  pushing 

  or 

  switch

  and  push  again    ACK/ENT    switch

Hereafter calculated latitude by ship's speed and true heading is indicated. 

 

(5)    Synchronization of the repeater compass 

*1

 

After the last azimuth operation completed, the repeater signal and the serial signal 
are outputted.    Turn "OFF" each repeater switch and adjust it to the  gyrocompass 
true heading, then turn "ON" the repeater switch. 

 

(6)    Settling time 

The time to "settled" requires approx. 6 hours maximum although it depends upon 
the starting condition. 
 
 

*1:   

When repeater is a serial signal type, this operation is not required because it will 
synchronize automatically, however, confirm that the indicated value coincides with "the true 
heading" selected by this system after the repeater switch turned "ON".

 

Содержание TG-8000 Series

Страница 1: ...Document No E10 1103 Gyro compass TG 8000 Series TG 8100 8600 Operator s Manual 2018 03 Marine Systems Company TOKYO KEIKI INC...

Страница 2: ......

Страница 3: ...tuation which if not avoided will result in death or serious injury Indicates an potentially hazardous situation which if not avoided could result in death or serious injury Indicates an potentially h...

Страница 4: ...tic steering system side Refer to the label attached position mentioned in the Operator s Manual for the automatic steering system TG 8100 S TG 8600 S Control unit TG 8100 D TG 8600 D Control unit 1 A...

Страница 5: ...se matters are described in each related item in this chapter with CAUTION or WARNING etc which should always be observed Read the Operator s Manual of the automatic steering system carefully preparin...

Страница 6: ...enerated in Chapter 3 Operation for determination method of the true heading When an alert regarding to LOG serial alert code P or U is generated and the true heading of the gyrocompass has not been d...

Страница 7: ...p turn to AUTO steering again 9 Warning regarding setting of latitude input system See page 3 11 CAUTION When an alert related to GNSS alert code c or d is generated and the true heading of the gyroco...

Страница 8: ...pass has not been determined once turn the steering mode to MANUAL or Non Follow Up then determine the true heading because erroneous heading information repeater signal and serial signal is possible...

Страница 9: ...tarts When MANUAL is selected stop after ship s speed setting is set to zero knot Also when turned off and on again with GNSS selected confirm that GNSS is operating properly 17 Warning regarding sett...

Страница 10: ...teering once turn the steering mode of the automatic steering system to MANUAL to prevent a large course changing and after confirming surrounding safety of own ship turn to AUTO steering again 23 War...

Страница 11: ...have large error All units operated by the heading information from this system in particular the automatic steering system etc should be immediately operated according to the individual emergency ope...

Страница 12: ...e should be taken because large course change may be happened 32 Warning regarding countermeasures when LOG serial signal communication abnormality is generated See page 3 25 CAUTION When an alert rel...

Страница 13: ...g countermeasures See page 4 2 CAUTION Before checking and replacement of fuses and disconnecting connecting of each unit connector printed circuit terminal cable turn OFF the power switch of the oper...

Страница 14: ...g may have error Turn the steering mode to MANUAL then determine the true heading to prevent course turning with larger angle 41 Warning regarding zero cross abnormality alert code 8 See page 4 7 CAUT...

Страница 15: ...l board 45 Warning regarding all repeaters does not operate See page 4 13 CAUTION When checking fuses turn OFF the power switch and further disconnect the power cable from the ship s distribution boar...

Страница 16: ...o be observed with respect to the manual are as follows 1 Please read this manual carefully Important items are described in this manual and it should thoroughly be read 2 Maintain this manual with ca...

Страница 17: ...ted power distribution lines with such testers Notations Items to be noted 1 Notation regarding to storage See page 5 7 NOTE Observe the following items for storage 1 Turn all power switches of this s...

Страница 18: ...nal heading sensor 1 4 1 3 8 Master compass running stop function Optional 1 4 1 4 Warranty conditions 1 5 CHAPTER 2 SPECIFICATION AND CONSTRUCTION 2 1 2 1 General 2 1 2 2 Configuration 2 1 2 3 Specif...

Страница 19: ...Failure phenomena and countermeasures 4 2 4 3 3 Replacement of fuse 4 14 4 4 Informed Items to TOKYO KEIKI service station 4 16 CHAPTER 5 MAINTENANCE AND CHECK 5 1 5 1 General 5 2 5 2 Periodical chec...

Страница 20: ...18 blank...

Страница 21: ...afe navigation and the proper exercise of navigational techniques is in no way reduced by the use of this equipment The following cautions should be observed 1 Always perform daily check to maintain n...

Страница 22: ...use the erroneous heading information repeater signal and serial signal is possible to be outputted to the outside Refer to 3 4 5 4 Countermeasures when LOG serial communication abnormality is generat...

Страница 23: ...er the following serial signal can be outputted 1 Output conformed to IEC61162 1 ed 2 2 Output conformed to IEC61162 2 These signals can be individually set for each circuit Refer to the finished plan...

Страница 24: ...um For setting up the departure date and time operate according to 2 Setting of timer start time in Chapter 3 Operation for 3 4 1 Start 1 3 7 Function by the external heading sensor When the external...

Страница 25: ...by misuse against the described maintenance handling and operation procedures in the manual 2 Failures and malfunctions caused from the repair performed by non TOKYO KEIKI or the service company not...

Страница 26: ...1 6 blank...

Страница 27: ...pare parts box 1 ea Master compass 1 ea Control unit 1 ea Spare parts box 1 ea Power supply unit When one gyrocompass is separate type in the two gyrocompasses system connected with Automatic Steering...

Страница 28: ...rate of turn ship s speed and alarms and the operating switches 3 Indicators Figure 7 2 It indicates operating conditions of this system and all setting values data Indicated contents can be selected...

Страница 29: ...mounting position is show below Refer to the finished plan maintained in the ship Mounting positions of the master compass operating panel power supply and control unit In case of PR 9000 automatic st...

Страница 30: ...ignal from GNSS E System internal communication abnormality 1 When the External heading sensor signal processing unit stopped its operation or the serial signal from the External heading sensor signal...

Страница 31: ...PWR FAIL W B 5 10304 ROTOR FAIL W B 6 10305 LEVEL FAIL W B 8 10320 ZERO CROSS W B A 10308 INNER COMM1 W B b 10309 INNER COMM2 W B c 10310 GNSS COMM W C B 1 d 10311 GNSS DATA W C B 1 E 10316 EXT SENSOR...

Страница 32: ...e situation Some alerts escalate to alarms if acknowledging after a certain time Yellowish orange Sound twice with short sound beep beep It repeats every 60 seconds until pressing ACK key Low C Cautio...

Страница 33: ...operating panel read explanation of this chapter referring to Figure 7 1 and Figure 7 2 attached in the end of this manual Also for the cases of the automatic steering system built in type and the con...

Страница 34: ...elect the system GYRO system is select For the system selection refer to 3 4 2 System selection in this chapter System select switch EXT It is used to select the system External heading sensor system...

Страница 35: ...ne gyrocompass system The meaning of a display of a mode indicator is the following S S G Steering Sensor Gyrocompass S S E Steering Sensor External sensor Gyt Gyrocompass true heading When GNSS commu...

Страница 36: ...lected as system either the gyrocompass true heading or the external heading sensor true heading is displayed Note Only shaded areas are indicated for one gyrocompass system The meaning of a display o...

Страница 37: ...following example is when the ship s speed input system is GNSS Gnss Speed When the ship s speed input system is MANUAL Hand Speed When the ship s speed input system is LOG Log Speed When the ship s...

Страница 38: ...n refer to 3 4 5 Alert in this chapter When alerts are not generated Error When an alert is generated Alerts are displayed in the data indicator in the generated order from the left as shown below The...

Страница 39: ...ture or 6 hours or more after starting Item 2 above Reconfirm Heading error correction Fixed error can be corrected in output heading if necessary Turn the power on switch on the gyrocompass operation...

Страница 40: ...g again Select the gyrocompass While pushing push switch Select the external heading sensor While pushing push switch Repeater synchronization Synchronize the each repeater indication with the selecte...

Страница 41: ...muth operation 2 Setting of timer start time 1 1 Indication automatically moves to current date and time indication after the power turning ON and software version number indicate finished The followi...

Страница 42: ...atically finishing last azimuth operation and turning to the set heading 4 hours before the set date and time 3 Setting of start heading After Software version number is indicated for the case without...

Страница 43: ...ading information repeater signal and serial signal is possible to be outputted to the outside Refer to 3 4 5 2 Countermeasures when GNSS communication abnormality is generated in Chapter 3 Operating...

Страница 44: ...s speed and true heading is indicated 5 Synchronization of the repeater compass 1 After the last azimuth operation completed the repeater signal and the serial signal are outputted Turn OFF each repea...

Страница 45: ...nce turn the steering mode to MANUAL or Non Follow Up then determined the true heading because the erroneous heading information repeater signal and serial signal is possible to be outputted to the ou...

Страница 46: ...S is selected for the ship s speed input system 2 Push SET switch and select one of either MANUAL GNSS LOG or LOG serial signal by or switch The indicators shows the following successively with blinki...

Страница 47: ...lect the filter constant by pushing or switch The filter constant can be set to 0 5 1 or 2 through 10 in 2 seconds step 4 Determine it by pushing ACK ENT switch 9 Confirmation of the true heading CAUT...

Страница 48: ...ch operation for 30 seconds 3 4 2 System selection CAUTION System selection switching may cause large change of the true heading During the automatic steering once turn the steering mode of the automa...

Страница 49: ...enerated in the system the alert indicator lamp goes blinking and buzzes Confirm the alert code indicated in the indicator and stop buzzer by pushing ACK ENT switch If the alert indicator lamp is stil...

Страница 50: ...to 3 4 1 Start 4 Setting of the latitude input system in this chapter Note When MANUAL is selected as the ship s speed input system the indicated latitude value is not updated Please enter the ship s...

Страница 51: ...ows when the master compass is in failure condition See the Figure 7 11 for the position of master compass power off switch When any abnormal condition or failure occurs in the master compass operate...

Страница 52: ...3 20 7 Once the heading information is changed to the gyrocompass synchronize the heading of each repeater with the heading from the gyrocompass...

Страница 53: ...witch When the alert indicator did not go off by pushing ACK ENT switch it shows that the alert conditions continues When the alert conditions continue confirm the alert code and take suitable counter...

Страница 54: ...is generated operate according to 3 4 5 2 Countermeasures when GNSS communication abnormality generated in this chapter Note This alert is generated only when GYRO is selected as the system selection...

Страница 55: ...em operate according to 3 4 4 3 Countermeasures when external heading sensor related communication abnormality is generated in this chapter 12 Master compass heading abnormality It is alerted when abn...

Страница 56: ...G serial signal data abnormality It is alerted when abnormality is generated in the serial signal from LOG When this alert is generated operate according to 3 4 5 4 Countermeasures when LOG serial sig...

Страница 57: ...SS Refer to 3 4 1 7 Setting of the ship s speed input system in this chapter 2 When GNSS is selected as the latitude input system select the other mode than GNSS Refer to 3 4 1 4 Setting of the latitu...

Страница 58: ...n the steering mode to MANUAL or Non Follow Up then determine the true heading because erroneous heading information repeater signal and serial signal is possible to be outputted to the outside Refer...

Страница 59: ...heading When abnormality related to LOG contact is generated the data indicator is blinking The gyrocompass true heading and the heading information outputted to the external which are currently indi...

Страница 60: ...3 28 blank...

Страница 61: ...unctions of this system 4 2 Before troubleshooting 1 Secure the ship s safety first according to the emergency steering procedure of the automatic steering system Then it is required to identify where...

Страница 62: ...hat the abnormality has still continued In such case confirm alert occurrence number and alert content from the data indicator Refer to 3 4 5 Alert in Chapter 3 Operating Method and check according to...

Страница 63: ...101 Voltage 24 V DC within 20 to 30 2 Automatic steering system built in type Model PR 9 1 D PR 9 1 E The system where both of the master compass and the control unit are built in the automatic steeri...

Страница 64: ...101 in the control unit Voltage 24 V DC within 20 to 30 No 2 gyrocompass side Input terminals of the main power supply between 2AC1 and 2AC2 of the external terminal board TB101 in the control unit Vo...

Страница 65: ...gency power supply between 1B and 1B of the external terminal board TB101 in the control unit Voltage 24 V DC within 20 to 30 No 2 gyrocompass side Input terminals of the main power supply between 2AC...

Страница 66: ...fuses are built in PR 9000 Automatic Steering System its location is different depending on the automatic steering system type also the power supply unit may be separated depending on the type Please...

Страница 67: ...to MANUAL then determine the true heading to prevent course turning with larger angle 1 Select the other mode other than AUTO of the automatic steering system 2 Turn OFF the power switch once and tur...

Страница 68: ...side of the control unit When it is built in PR 9000 Automatic Steering System the connection is different depending on the automatic steering system type Perform it referring to the finished plan of...

Страница 69: ...alert is not generated in the above item 2 operate according to 3 4 1 Start in Chapter 3 Operating Method 4 When an alert is generated again in the above item 2 turn OFF the power switch of this syst...

Страница 70: ...of the control unit GTERM PWB TB21 MT b Automatic steering system built in type Model PR 9 37D PR 9 47D PR 9 37E and PR 9 47E Connector of the master compass MTTRM PWB J2 Connector of the control unit...

Страница 71: ...heading sensor operates properly If not operate it according to the Operator s Manual for the external heading sensor 3 If it was not recovered after performed the above item 2 take necessary counterm...

Страница 72: ...lert code 1 in this chapter 2 If the above item 1 does not show any problem check fuses after disconnected the main emergency power supply One gyrocompass system Fuse XF101 and XF102 are located in th...

Страница 73: ...rd GTERM PWB Refer to the finished plan maintained in the ship for the details of repeater s connection circuit Refer to Figure 7 5 Step type F5 to F9 F11 to F14 1 A Serial type F1 to F10 1 A 3 In the...

Страница 74: ...power supply and the emergency power supply from the ship s distribution board When fuse has blown investigate its cause It will occur again unless the cause is removed if replaced with the same capa...

Страница 75: ...in each unit To open the holder turn counterclockwise with pressing top of the holder After replaced the fuse turn clockwise with pressing top of the holder to close it 3 Replacement of the protection...

Страница 76: ...its dealer agency in your area to request advice with the following items informed 1 Ship s name and owner 2 Equipment name type and serial no 3 Where is the ship now 4 Trouble symptoms Error name 5 W...

Страница 77: ...f electronic circuits having high reliability However it is impossible to say that no failure should happen Accordingly the check and maintenance described in this chapter should be sincerely carried...

Страница 78: ...onance vibration Check and re tighten the related screws at need 3 Most parts used in the main sections of this system are electronic electric parts Occurrence of electronic parts trouble themselves i...

Страница 79: ...k items a Confirm that the value of each repeater synchronizes with the displayed true heading on the operating panel b Confirm that the displayed latitude on the operating panel coincides with the cu...

Страница 80: ...e Check items a Confirm tightness of fixing screws in mechanical sections and connecting screws in the terminal board Re tighten if loosened b Confirm connecting and wire wearing conditions at connect...

Страница 81: ...3 are attached to this system ITE M NAME OF PART OUTLINE Quantity REMARKS WORKING SPARE PERSET PER VESS FOR MASTER COMPASS B 1 FUSE 1 1 2 250V 12A 10038616 FOR CONTROL UNIT B 2 FUSE 1 1 2 250V 20A MF...

Страница 82: ...eneration of corrosive gas breeding of bacteria such as mold or intrusion of insects and small animals 4 Cover the system with a plastic sheet etc when generation of dust is foreseen When welding work...

Страница 83: ...ced when started the system again Leveling operation Operation to keep the sensor horizontal Magnetic compass system The heading detector is mounted on the magnetic compass and detected heading signal...

Страница 84: ...6 2 blank...

Страница 85: ...Figure 7 6 Automatic steering system built in type of one Gyrocompass system Figure 7 7 Stand alone type Control unit of two Gyrocompasses system Figure 7 8 Automatic steering system built in type of...

Страница 86: ...7 2 CONTROL UNIT OPERATING UNIT Fig 7 1 Outline of control unit One Gyro compass system...

Страница 87: ...GYRO DISP SWITCH SYSTEM SELECT SWITCH EXT SET SWITCH DATA DISPLAY ACK ENT SWITCH MODE DISPLAY SWITCH ALERT INDICATOR A Alarm Color Red W Warning Color Yellowish Orange C Caution Color Yellow SYSTEM SE...

Страница 88: ...7 4 Fig 7 3 Master compass FUSE F1 12A...

Страница 89: ...7 5 Fig 7 4 Minimum type Control unit of one compass system F1 F5 1A F6 F10 1A CONTROL UNIT ICNT PWB ICNT PWB...

Страница 90: ...7 6 CONTROL UNIT GTERM PWB DTERM PWB GTERM PWB F1 F14 1A F15 15A F16 F17 3 15A DTERM PWB XF17 10A XF18 19 3 15A Fig 7 5 Stand alone type Control unit of one Gyro compass system...

Страница 91: ...7 7 AUTOMATIC STEERING SYSTEM CONTROL UNIT COMPASS OPERATING PANEL XF101 6 3A XF102 10A Fig 7 6 Automatic steering system built in type of one Gyro compass system Gyro compass built in type...

Страница 92: ...7 8 CONTROL UNIT CTERM PWB DTERM PWB CTERM PWB XF101 6 3A XF102 20A DTERM PWB XF17 10A XF18 19 3 15A Fig 7 7 Stand alone type Control unit of two Gyro compass system...

Страница 93: ...OPERATING PANEL No 1 GYRO COMPASS OPERATING PANEL Automatic Steering System GTERM PWB DTERM PWB CTERM PWB CTERM PWB Fig 7 8 Automatic steering system built in type of two Gyro compass system Two Gyro...

Страница 94: ...PANEL No 1 GYRO COMPASS OPERATING PANEL Automatic Steering System GTERM PWB DTERM PWB CTERM PWB Power Supply Unit Fig 7 9 Automatic steering system built in type of two Gyro compass system One master...

Страница 95: ...S OPERATING PANEL No 1 GYRO COMPASS OPERATING PANEL Automatic Steering System GTERM PWB DTERM PWB CTERM PWB CTERM PWB Fig 7 10 Automatic steering system built in type of two Gyro compass system Two ma...

Страница 96: ...7 12 Power Supply Unit Fig 7 11 Power Supply Unit...

Страница 97: ...Control Unit MASTER COMPASS POWER SWITCH S1 No 1 MASTER COMPASS POWER SWITCH S1 No 2 MASTER COMPASS POWER SWITCH S1 TG 8100 I TG 8600 I Control Unit AUTOMATIC STEERING SYSTEM MASTER COMPASS POWER SWIT...

Страница 98: ...7 14 blank...

Страница 99: ...to TOKYO KEIKI service station 4 16 Items to be observed with respect to the manual 14 Last azimuth 3 9 3 10 3 12 6 1 Magnetic compass system 1 3 1 4 5 2 6 1 Maintenance and Check 5 1 5 2 Measures wh...

Страница 100: ...rection 1 1 1 4 6 1 Start 1 4 2 2 3 1 3 7 3 9 3 10 3 12 3 18 4 6 4 7 4 8 4 9 Storage method 5 6 Synchronization of the repeater compass 3 12 System selection 1 3 1 4 3 2 3 8 3 17 3 16 3 19 3 21 3 22 3...

Страница 101: ...the displayed true heading on the operating panel b Confirm that the displayed latitude on the operating panel coincides with the current latitude c Measure error with observation if possible d Confir...

Страница 102: ...tions and connecting screws in the terminal board Re tighten if loosened b Confirm connecting and wire wearing conditions at connecting wire mounting points and wire bases c Confirm operating conditio...

Страница 103: ...vc tokyo keiki co jp 81 898 23 6161 81 898 23 7731 Hokkaido Service Station 2 2 12 Kikusui Nijo Shiroishi ku Sapporo city Hokkaido 003 0802 JAPAN hokkaido ss tokyo keiki co jp 81 11 816 6291 81 11 816...

Страница 104: ......

Страница 105: ...0 1103 Mar 07 2018 First Edition 2 16 46 MINAMI KAMATA OTA KU TOKYO 144 8551 JAPAN Marine Systems Company Tel 81 3 3737 8611 Fax 81 3 3737 8663 Notice This operator s manual must not be copied or repr...

Отзывы: