10-19
No. Log
When logs are generated
74
Set: Device/Other-Language
When the OK key on the " Language " setting screen in the
Device/Other is touched
75
Set: Security-Security Mode
When the OK key on the " Security Mode " setting screen in the Security
is touched
76
Set: Security-Key lock
When the OK key on the " Key lock " setting screen in the Security is
touched
77
Add: Security-User Regist
When a new user is added in the " user Regist." setting in Security
78
Edit: Security-User Regist
When an existing user is edited in the "user Regist." setting in Security
79
Delete: Security-User Regist
When an existing user is deleted in the " user Regist." setting in Security
80
Execute: Remote AI Retry
When the remote AI is reconnected
81
Execute: ModbusMas Retry
When the Modbus master is reconnected
82
Execute: Addition reset
When accumulation is reset with the FUNC button
83
Auto Logout
When no operations are performed for five minutes (only when "Auto +
Manual" is set to the logout setting in the extended security mode)
84
Execute: Register production
information.
Setting in production information setting by FUNC button When key is
touched
10.21 Option item
■
Option
Item
Code
Shunt resistance for a direct-current input
(250Ω±0.1%)
HMSU3081A11
The terminator for RS-
485 (200Ω)
WMSU0303A01
DI/DO cable (1m)
WMSU0468A01
DI/DO cable (3m)
WMSU0468A02