TOELLNER TOE 9261 Скачать руководство пользователя страница 2

 

Contents 

Page 

 

 

TOELLNER Electronic Instrumente GmbH 

 

1.

 

Introduction ............................................................................................................. 4

 

1.1

 

Features ................................................................................................................................ 4

 

1.1.1

 

General feature set ............................................................................................................. 4

 

1.1.2

 

Overview of features ........................................................................................................... 5

 

1.2

 

Model overview ..................................................................................................................... 5

 

1.3

 

Schematic diagram for TOE 9261 ......................................................................................... 5

 

2.

 

Operation ................................................................................................................. 6

 

2.1

 

Startup ................................................................................................................................... 6

 

2.1.1

 

Installation and ventilation .................................................................................................. 6

 

2.1.2

 

Preparations ....................................................................................................................... 6

 

2.2

 

Description of the controls ..................................................................................................... 7

 

2.2.1

 

Front panel controls ............................................................................................................ 7

 

2.2.2

 

Rear panel controls............................................................................................................. 9

 

2.3

 

General operation features .................................................................................................... 9

 

2.4

 

Power switch operation ......................................................................................................... 9

 

2.4.1

 

Connection of the input voltage source............................................................................... 9

 

2.4.2

 

Insertion of artificial networks ............................................................................................. 9

 

2.4.3

 

Application of the internal input buffer capacitor ................................................................. 9

 

2.4.4

 

Connection of the consumer for switching the positive supply line ................................... 10

 

2.4.5

 

Connection of the consumer for switching a ground line (minus) ..................................... 10

 

2.4.6

 

Connection of the control signal ....................................................................................... 10

 

2.4.7

 

Control of switching paths and operation of the consumer ............................................... 10

 

2.4.8

 

Display of the switching states .......................................................................................... 11

 

2.4.9

 

Use of the branch path ..................................................................................................... 11

 

2.4.10

 

High-impedance base load ............................................................................................... 12

 

2.4.11

 

PWM operation of a consumer ......................................................................................... 12

 

2.5

 

Operation of the signal line switches ................................................................................... 13

 

2.5.1

 

Connection ....................................................................................................................... 13

 

2.5.2

 

Control .............................................................................................................................. 13

 

2.6

 

Protection ............................................................................................................................ 14

 

2.6.1

 

Overcurrent and short-circuit protection of the switching paths ........................................ 14

 

2.6.2

 

Input overcurrent protection .............................................................................................. 14

 

2.6.3

 

Protection against exceeding of the maximum switching frequency ................................. 14

 

2.6.4

 

Excessive temperature protection .................................................................................... 15

 

3.

 

Configuring for 19" rack mount .......................................................................... 16

 

3.1

 

19" adapter set (2 HU) for 1x TOE 9261 (option) ................................................................ 16

 

3.2

 

19" adapter set (2 HU) for two Toellner Instruments ½ 19" (option) .................................... 17

 

4.

 

Technical data ....................................................................................................... 18

 

4.1

 

Technical data TOE 9261 .................................................................................................... 18

 

4.2

 

General data ........................................................................................................................ 20

 

4.3

 

Specification of the high-current connectors ........................................................................ 20

 

5.

 

Views ...................................................................................................................... 21

 

 

Содержание TOE 9261

Страница 1: ...n Manual Electronic Switch TOE 9261 9261E Manual Rev05 doc R TOELLNER ELECTRONIC INSTRUMENTE GMBH Gahlenfeldstra e 31 58313 Herdecke Germany 49 0 23 30 97 91 91 Fax 49 0 23 30 97 91 97 E Mail info toe...

Страница 2: ...switching a ground line minus 10 2 4 6 Connection of the control signal 10 2 4 7 Control of switching paths and operation of the consumer 10 2 4 8 Display of the switching states 11 2 4 9 Use of the b...

Страница 3: ...ual When operating electronic equipment certain parts in these devices are necessarily under dangerous voltage Non observance of the warnings may therefore result in severe bodily injury or damage to...

Страница 4: ...a feeding source to the connected consumer The branch path in this case is arranged parallel to the consumer and can be optionally connected via a DIL switch It serves as needed to selectively dischar...

Страница 5: ...h TTL CMOS 5 V and LVCMOS 3 3 V Permissible switching frequency DC up to 100 kHz Protected against overcurrent short circuit excessive temperature excessive switching frequency 1 2 Model overview Seri...

Страница 6: ...result in a hazardous condition for the device No intentional interruption of the protective earth connection is permitted Observe local regulations for earthing Ensure that only fuses of the specifi...

Страница 7: ...or rear CONTROL input 3 Front panel BNC input CONTROL for controlling the switching state both for the power switch and the signal line switches 2 4 7 Control of switching paths and operation of the c...

Страница 8: ...e illuminated 12 Red OVL LED Overload Comes on when a shutdown has occurred due to one of the following fault conditions Max switching frequency of 100 kHz on the control input has been exceeded Overc...

Страница 9: ...f the consumer for switching a ground line the input voltage should be connected to this socket and to the Minus socket otherwise to the left hand Plus socket and the Minus socket The applied voltage...

Страница 10: ...also the above mentioned improper load current flow via the 0 1 resistor is automatically locked Warning In the described switch configuration the positive supply line from the voltage source to the c...

Страница 11: ...PULL UP ON to ON the internally evaluated level changes to High resulting in switching path S1 becoming conductive and switching path S2 non conductive In the configuration for switching the positive...

Страница 12: ...e rise and fall times are lengthened High buffer capacities with low series resistance values ESR can also result in triggering of the overcurrent fuse Warning Feedback from the buffered load side to...

Страница 13: ...ged by excessive ripple current loads 2 5 Operation of the signal line switches 2 5 1 Connection To switch signal lines they are routed through the bidirectional switches S3 S6 They are connected usin...

Страница 14: ...reset is accomplished by turning the unit off and on using the mains switch The cause of the overcurrent or short circuit must be identified and eliminated 2 6 2 Input overcurrent protection The input...

Страница 15: ...n responds to excessive component temperatures in the unit This protection is provided in two stages For continuous operation at high voltage high current and high switching frequency the fan speed is...

Страница 16: ...to the 19 adapter piece 1 Insert this unit in replacement for the fill strip and screw it on to the front panel using the hexagon socket screws 6 4 For the other side attach the adapter bracket 3 to...

Страница 17: ...ice Pull the four fill strips 5 from the side 3 For the outer faces of the devices attach a handle 4 to a 19 adapter piece 1 each using the countersunk screws 7 Insert these units in replacement for t...

Страница 18: ...ower switch switching times Rise time tr with reference resistor 1 With connected input buffer capacitor Without buffer capacitor input cable 0 50 m twisted Without buffer capacitor input cable 1 20 m...

Страница 19: ...Increase in fan speed Stage 2 Switching off of switching paths display OVL Switching off and on again using mains switch following appropriate cooling period Power switch is not reverse polarity prot...

Страница 20: ...luded accessories 1 mains cable 2 terminal blocks for signal line switches 1 Instruction Manual Optional accessories 0 50 m connection cable with 1 safety socket red TOE 9260 22 0 50 m connection cabl...

Страница 21: ...t 8 Selectable base load 10 k or 100 k with green indication LED 9 Power switch branch path incl red indication LED 10 0 series resistor for branch path with green indication LED 11 0 1 series resisto...

Отзывы: