3. 

Configuring for 19" rack mount 

3.1 

19" adapter set (2 HU) for 1x TOE 9261 (option) 

The series 

TOE 9261

 Electronic Switches are 19" rack-capable tabletop devices. By using 

the optional 

TOE 9521

 one 

TOE 9261

 can be easily converted for 19" 2 HU rack mount.  

The optional 19" adapter set 

TOE 9521

 includes a 19" adapter piece with handle and a 19" 

compensation panel with handle as well as the necessary installation materials. 
 

Reconfiguring from 1x TOE 9261 to 19" rack mount 

1.  Use the included TX 20 screwdriver to remove the feet from the Electronic Switch. First 

remove the rubber inserts on the front feet. 

2.  Use the included Allen wrench to remove the two inner screws (6) on the left and right 

side of the front panel of the Electronic Switch. Pull the two fill strips (5) from the side. 

3.  For the left or right side attach 

a handle (4) with countersunk screws (7) to the 19” 

adapter piece (1). Insert this unit in replacement for the fill strip and screw it on to the 
front panel using the hexagon socket screws (6). 

4.  F

or the other side attach the adapter bracket (3) to the 19” compensation panel (2) using 

the hexagon socket screws (6), the spring washers (9), and the nuts (8). Also attach the 
handle (4) with countersunk screws (7) to the 19” compensation panel (2). Insert this pre-
assembled unit in replacement for the fill strip and screw it on to the front panel using the 
hexagon socket screws (6). 

5.  Use the thread-forming screws (10) to attach the adapter bracket (3) of the above-

mentioned unit additionally to the side holes provided as shown in the diagram. 

 

 

 

 

  1:  19" adapter piece 2 HU 
  2:  19" compensation panel 2 HU 
  3:  Adapter bracket 
  4:  Handle 
  5:  Fill strip 
  6:  Hexagon socket screw M3 x 8 
  7:  Countersunk screw M5 x 12 
  8:  Nut M3 
  9:  Spring washer for M3 
 10:  Thread-forming screw 3.9 x 6.5 

 
 

Installing in the 19" rack 

The 19" unit must be located on the device side on a slide rail. This slide rail as well as the 
fasteners needed for attaching the unit in the 19" rack are not included in the scope of 
delivery for this option. 

 

Содержание TOE 9261

Страница 1: ...n Manual Electronic Switch TOE 9261 9261E Manual Rev05 doc R TOELLNER ELECTRONIC INSTRUMENTE GMBH Gahlenfeldstra e 31 58313 Herdecke Germany 49 0 23 30 97 91 91 Fax 49 0 23 30 97 91 97 E Mail info toe...

Страница 2: ...switching a ground line minus 10 2 4 6 Connection of the control signal 10 2 4 7 Control of switching paths and operation of the consumer 10 2 4 8 Display of the switching states 11 2 4 9 Use of the b...

Страница 3: ...ual When operating electronic equipment certain parts in these devices are necessarily under dangerous voltage Non observance of the warnings may therefore result in severe bodily injury or damage to...

Страница 4: ...a feeding source to the connected consumer The branch path in this case is arranged parallel to the consumer and can be optionally connected via a DIL switch It serves as needed to selectively dischar...

Страница 5: ...h TTL CMOS 5 V and LVCMOS 3 3 V Permissible switching frequency DC up to 100 kHz Protected against overcurrent short circuit excessive temperature excessive switching frequency 1 2 Model overview Seri...

Страница 6: ...result in a hazardous condition for the device No intentional interruption of the protective earth connection is permitted Observe local regulations for earthing Ensure that only fuses of the specifi...

Страница 7: ...or rear CONTROL input 3 Front panel BNC input CONTROL for controlling the switching state both for the power switch and the signal line switches 2 4 7 Control of switching paths and operation of the c...

Страница 8: ...e illuminated 12 Red OVL LED Overload Comes on when a shutdown has occurred due to one of the following fault conditions Max switching frequency of 100 kHz on the control input has been exceeded Overc...

Страница 9: ...f the consumer for switching a ground line the input voltage should be connected to this socket and to the Minus socket otherwise to the left hand Plus socket and the Minus socket The applied voltage...

Страница 10: ...also the above mentioned improper load current flow via the 0 1 resistor is automatically locked Warning In the described switch configuration the positive supply line from the voltage source to the c...

Страница 11: ...PULL UP ON to ON the internally evaluated level changes to High resulting in switching path S1 becoming conductive and switching path S2 non conductive In the configuration for switching the positive...

Страница 12: ...e rise and fall times are lengthened High buffer capacities with low series resistance values ESR can also result in triggering of the overcurrent fuse Warning Feedback from the buffered load side to...

Страница 13: ...ged by excessive ripple current loads 2 5 Operation of the signal line switches 2 5 1 Connection To switch signal lines they are routed through the bidirectional switches S3 S6 They are connected usin...

Страница 14: ...reset is accomplished by turning the unit off and on using the mains switch The cause of the overcurrent or short circuit must be identified and eliminated 2 6 2 Input overcurrent protection The input...

Страница 15: ...n responds to excessive component temperatures in the unit This protection is provided in two stages For continuous operation at high voltage high current and high switching frequency the fan speed is...

Страница 16: ...to the 19 adapter piece 1 Insert this unit in replacement for the fill strip and screw it on to the front panel using the hexagon socket screws 6 4 For the other side attach the adapter bracket 3 to...

Страница 17: ...ice Pull the four fill strips 5 from the side 3 For the outer faces of the devices attach a handle 4 to a 19 adapter piece 1 each using the countersunk screws 7 Insert these units in replacement for t...

Страница 18: ...ower switch switching times Rise time tr with reference resistor 1 With connected input buffer capacitor Without buffer capacitor input cable 0 50 m twisted Without buffer capacitor input cable 1 20 m...

Страница 19: ...Increase in fan speed Stage 2 Switching off of switching paths display OVL Switching off and on again using mains switch following appropriate cooling period Power switch is not reverse polarity prot...

Страница 20: ...luded accessories 1 mains cable 2 terminal blocks for signal line switches 1 Instruction Manual Optional accessories 0 50 m connection cable with 1 safety socket red TOE 9260 22 0 50 m connection cabl...

Страница 21: ...t 8 Selectable base load 10 k or 100 k with green indication LED 9 Power switch branch path incl red indication LED 10 0 series resistor for branch path with green indication LED 11 0 1 series resisto...

Отзывы: