TOELLNER TOE 9261 Скачать руководство пользователя страница 11

 

Section 2 

– Operation 

 

 

TOELLNER Electronic Instrumente GmbH 

11 

This results in the following possible operating conditions: 

Configuration of TOE 9261 

and consumer 

DIL switch 

 CONTROL / INV 

 

CONTROL 

signal 

Consumer status 

Switching of positive supply line 

-- 

Low 

Disconnected (OFF) 

 

-- 

High 

Supplied (ON) 

 

 INV 

 

Low 

Supplied (ON) 

 

 INV 

 

High 

Disconnected (OFF) 

Switching of return line (ground) 

-- 

Low 

Supplied (ON) 

 

-- 

High 

Disconnected (OFF) 

 

 INV 

 

Low 

Disconnected (OFF) 

 

 INV 

 

High 

Supplied (ON) 

 

The appropriate setting of the 

 CONTROL / INV 

 DIL switch can therefore be selected 

depending on the desired configuration (switching of positive supply line or of return line) and 
the desired function of the control signal (High level should lead to supply of consumer or to 
disconnection from the supply). 

In the disconnected status of the consumer, a buffer stage present in the consumer and 
possibly still charged is discharged if one of the two following cases exists: 

 

TOE 9261

 and consumer were connected in the configuration for switching the positive 

supply line, and one of the two DIL switches 

 S2 + 0.1 

Ω 

 and 

 S2 + 0 

Ω 

 is set to 

 ON 

 

(

 2.4.9 Use of the branch path). 

 

TOE 9261

 and consumer were connected in the configuration for switching the return line 

(ground), and the DIL switch 

 S1 ENABLE 

 was not set to 

 OFF 

 

Note 

If the 

CONTROL 

input is not connected or controlled but left in a high-impedance state, 

this is evaluated as Low level. If in this case either the DIL switch 

 CONTROL / INV 

 is set to 

 INV 

 or the DIL switch 

 PULL-UP / ON 

 to 

 ON 

, the internally evaluated level changes to High, 

resulting in switching path 

S1

 becoming conductive and switching path 

S2

 non-conductive. 

In the configuration for switching the positive supply line, the consumer is then 
permanently connected to the supplying voltage source. 
In the configuration for switching the return line (ground), on the other hand, the consumer 
is permanently connected to the supplying voltage source if 

– with the 

CONTROL 

input left 

in a high-impedance state 

– the named DIL switches are either both in the left-hand or 

both in the right-hand positions. 

 
 

2.4.8 

Display of the switching states 

A conductive path 

S1

 or 

S2

 is indicated by the red LED at the related switch symbol. To 

ensure always the perceptibility of the display, in case of high frequencies or short High or 
Low pulses of the switching signal at the 

CONTROL 

input, not the actual fast changing 

switching states are displayed, but it is calculated a slowed down signal for the display LEDs. 
The switching paths themselves, however, are controlled by the timing of the switching 
signal. 

 

2.4.9 

Use of the branch path 

In the configuration for switching the positive supply line, 

S2

 represents the load parallel 

branch path. The switching state of the branch path 

S2

 is always complementary to the state 

of the longitudinal path 

S1

. This means the consumer can be jumpered with 

S2

, while 

S1

 is 

open (not conducting). This allows for example a buffer stage in the consumer to be 
discharged. 

To achieve the fastest possible discharging without a series resistor, DIL switch 

 S2 + 0 

Ω 

 

must be set to 

 ON 

. For indication the green LED next to the related switch symbol is 

illuminated. 

Содержание TOE 9261

Страница 1: ...n Manual Electronic Switch TOE 9261 9261E Manual Rev05 doc R TOELLNER ELECTRONIC INSTRUMENTE GMBH Gahlenfeldstra e 31 58313 Herdecke Germany 49 0 23 30 97 91 91 Fax 49 0 23 30 97 91 97 E Mail info toe...

Страница 2: ...switching a ground line minus 10 2 4 6 Connection of the control signal 10 2 4 7 Control of switching paths and operation of the consumer 10 2 4 8 Display of the switching states 11 2 4 9 Use of the b...

Страница 3: ...ual When operating electronic equipment certain parts in these devices are necessarily under dangerous voltage Non observance of the warnings may therefore result in severe bodily injury or damage to...

Страница 4: ...a feeding source to the connected consumer The branch path in this case is arranged parallel to the consumer and can be optionally connected via a DIL switch It serves as needed to selectively dischar...

Страница 5: ...h TTL CMOS 5 V and LVCMOS 3 3 V Permissible switching frequency DC up to 100 kHz Protected against overcurrent short circuit excessive temperature excessive switching frequency 1 2 Model overview Seri...

Страница 6: ...result in a hazardous condition for the device No intentional interruption of the protective earth connection is permitted Observe local regulations for earthing Ensure that only fuses of the specifi...

Страница 7: ...or rear CONTROL input 3 Front panel BNC input CONTROL for controlling the switching state both for the power switch and the signal line switches 2 4 7 Control of switching paths and operation of the c...

Страница 8: ...e illuminated 12 Red OVL LED Overload Comes on when a shutdown has occurred due to one of the following fault conditions Max switching frequency of 100 kHz on the control input has been exceeded Overc...

Страница 9: ...f the consumer for switching a ground line the input voltage should be connected to this socket and to the Minus socket otherwise to the left hand Plus socket and the Minus socket The applied voltage...

Страница 10: ...also the above mentioned improper load current flow via the 0 1 resistor is automatically locked Warning In the described switch configuration the positive supply line from the voltage source to the c...

Страница 11: ...PULL UP ON to ON the internally evaluated level changes to High resulting in switching path S1 becoming conductive and switching path S2 non conductive In the configuration for switching the positive...

Страница 12: ...e rise and fall times are lengthened High buffer capacities with low series resistance values ESR can also result in triggering of the overcurrent fuse Warning Feedback from the buffered load side to...

Страница 13: ...ged by excessive ripple current loads 2 5 Operation of the signal line switches 2 5 1 Connection To switch signal lines they are routed through the bidirectional switches S3 S6 They are connected usin...

Страница 14: ...reset is accomplished by turning the unit off and on using the mains switch The cause of the overcurrent or short circuit must be identified and eliminated 2 6 2 Input overcurrent protection The input...

Страница 15: ...n responds to excessive component temperatures in the unit This protection is provided in two stages For continuous operation at high voltage high current and high switching frequency the fan speed is...

Страница 16: ...to the 19 adapter piece 1 Insert this unit in replacement for the fill strip and screw it on to the front panel using the hexagon socket screws 6 4 For the other side attach the adapter bracket 3 to...

Страница 17: ...ice Pull the four fill strips 5 from the side 3 For the outer faces of the devices attach a handle 4 to a 19 adapter piece 1 each using the countersunk screws 7 Insert these units in replacement for t...

Страница 18: ...ower switch switching times Rise time tr with reference resistor 1 With connected input buffer capacitor Without buffer capacitor input cable 0 50 m twisted Without buffer capacitor input cable 1 20 m...

Страница 19: ...Increase in fan speed Stage 2 Switching off of switching paths display OVL Switching off and on again using mains switch following appropriate cooling period Power switch is not reverse polarity prot...

Страница 20: ...luded accessories 1 mains cable 2 terminal blocks for signal line switches 1 Instruction Manual Optional accessories 0 50 m connection cable with 1 safety socket red TOE 9260 22 0 50 m connection cabl...

Страница 21: ...t 8 Selectable base load 10 k or 100 k with green indication LED 9 Power switch branch path incl red indication LED 10 0 series resistor for branch path with green indication LED 11 0 1 series resisto...

Отзывы: