33
8.3. M-802RC
The
M-802RC
has the same functionality as the
M-800RC
volume control, but it includes 2 additional
analog
M-802RC
requires/consumes 2x digital output channels of in total 4 available digital output channels of
outputs. The device includes a build in D/A converter processing digital audio AES3 signals from
M-8080D
M-8080D
.
.
a. LC-Display
It displays the volume level and the
signal level for a dedicated output.
b. Volume and routing control
Turn the button left or right to adjust
the volume.
Push the button to access to the inputs
and outputs routing function.
c. RD IN
Connection to
M-8080D
or
M-804EX
. The
maximum CAT 5e cable length is
100 meters
.
Attention:
1
)
M-800RM / M-822IO / M-802RC
(with audio transmission)
can only be connected to the RD port of the
M-8080D
or the RD EXP port 1 of
M-804EX
.
2
)
M-800RC / M-800RCT
(with control function) can link each other.
d. Analog OUT
2 channel analog line Outputs assigned to RD port 9 / 10 or 11 / 12 of
M-8080D
.
Wall installation instructions:
1. First unscrew the screw on the bottom of the device with a screwdriver.
2. Fix the back plate to the wall. Screw both ends to the wall. Check for firmness or crooked nails.
3. Insert the distributed network cable into the RD IN port, Connect the analog output cable, and snap the
device to the back plate. Tighten the bottom with screws.
4. Cover the decorative panel.
RD IN