8.2. M-800RC
This volume controller can be assigned to any output of the
M-8080D
. It can also route any input to any
output like in the Matrix menu of the Editor Software.
a. LC-Display
It displays the volume level and the
signal level for a dedicated output.
b. Volume and routing control
Turn the button left or right to adjust
the volume.
Push the button to access to the inputs
and outputs routing menu.
c. RD IN
Connection to
M-8080D
or
M-804EX
.
The maximum CAT 5e cable length is
The maximum CAT 5e cable length for daisy chain
100 meters
in total from
M-8080D
RD port to last
controller.
100 meters
.
d. RD EXP
Daisy connection for additional remote controller (4 controllers max).
Attention:
1
)
M-800RM / M-822IO / M-802RC
(with audio transmission) can only be connected to the RD port of
the
M-8080D
or the RD EXP port 1 of
M-804EX
.
2
)
M-800RC / M-800RCT
(with control function) can link each other.
Wall installation instructions:
1. First unscrew the screw on the bottom of the device with a screwdriver.
2. Fix the back plate to the wall. Screw both ends to the wall. Check for firmness or crooked nails.
3. Insert the distributed network cable into the RD IN port, and snap the device to the back plate. Tighten
the bottom with screws.
4. Cover the decorative panel.
RD IN RD EXP