![Toa D-2008SP Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/toa/d-2008sp/d-2008sp_operation-manual_1122873019.webp)
Digital mixer D-2000 Series
TOA Corporation
TOA Corporation
TOA Corporation
TOA Corporation
19/37
Status Information
D-2008SP connection establishment status
Status data is transmitted from the D-2008SP when the TCP connection is established.
DFH, 01H,01H
Gate Status
The D-2008SP transmits the current status data when Gate Status changed in Gate Status
Notification started.
E6
E6
E6
E6H, 03H, 0
H, 03H, 0
H, 03H, 0
H, 03H, 00
0
0
0H, <
H, <
H, <
H, <Channel
Channel
Channel
Channel Number>, <
Number>, <
Number>, <
Number>, <OPEN/CLOSE
OPEN/CLOSE
OPEN/CLOSE
OPEN/CLOSE>
>
>
>
<Channel Number>
00H - 21H (Audio In channel 1 - 34)
<OPEN/CLOSE>
00H: OPEN
01H: CLOSE
Example of the CLOSE status data of Audio Input 1
E6H, 03H, 00H, 00H, 01H
External Control Switch Press Status
The D-2008SP transmits the current status data when Key Press Status changed in Auto Status
Notification started.
It is necessary for Console Function Key to set External Control Switch setting.
E6
E6
E6
E6H, 0
H, 0
H, 0
H, 04
4
4
4H, 0
H, 0
H, 0
H, 01
1
1
1H,
H,
H,
H,
<Console 1umber>, <Key 1umber>, <O1/OFF>
<Console Number>
00H - 03H
:
Console ID 1 - 4
<Key Number>
00H - 07H
:
Function Key 1 - 8
<ON/OFF>
00H: OFF
01H: ON