A pop-up menu will appear:
•
This asks you to place the 9000 unit BACK-UP mode.
•
To enter BACKUP MODE- From power off, press and hold INPUT 8, ENTER &
POWER buttons on the 9000 unit’s front panel simultaneously.
•
The 9000 display then reads: “BACKUP MODE”.
•
Press “OK” on the menu.
•
The PC begins to upload the currently loaded configuration template to the 9000 unit.
•
When this occurs, all other settings in the 9000 unit’s memory are erased.
•
Also, before uploading, make sure the 9000 unit is set the same mode (MATRIX or
MIXER) as the configuration you are trying to load.
•
It may be necessary to adjust your serial port # and baud rate to effect proper serial
communication with your PC. You can find these under the “Communication> Setting”
menu. The default for this is Port 1, speed 57,600 baud.
For Download:
Essentially, the same process, except that you will select “DOWNLOAD 9000 TO PC”
from the “COMMUNICATIONS” menu. You will receive the same prompt and set up the 9000
for BACKUP mode as before. All memory and configuration data currently in the 9000 unit
will download to your PC and be saved to a designated file as either an .mtx (matrix) or .mix
(mixer) file.
In either procedure, all 32 presets, as well as global settings are stored to the unit or the PC.
c. What to do if I’ve forgotten my security password?
Not to worry. We’ve provided a back door to getting into the front panel. When you
encounter an “ENTER PASSWORD” screen, implement the following button push:
PRESS and HOLD “INPUT 1”, then press the “ESC/BACK” key and the “
S
” arrow key
simultaneously. This will allow security access to menu functions which had been locked
38
out.