8. Output Channel label.
A right-click on an output channel’s label accesses a COPY /
PASTE function, allowing the channel’s settings to be copied to other output channels.
9. VOX.
Each Mic/line input (D-001T/D-001R) may be assigned a VOX function (similar to
gate) allowing the channel to be activated for paging by voice or audio input (assignable in
the EVENT Page). Adjustable threshold and release time.
10. Ducker.
This is activated for inputs which will function as higher priority paging signals
(Mic/ZP) to attenuate or mute BGM (Background Music) sources automatically. MATRIX
mode provides 8 paging priority levels which can “Duck” sources which are lower in priority.
11. EVENT.
This accesses the EVENT page, which lists all 32 EVENT presents. Input source,
activation trigger (contact, VOX or NONE) and output assignments are selected in this
page. Any ROUTE or BASE EVENT can be assigned to be the power-on default.
12. CLOSE.
This button closes the I/O Module Settings Page.
g. Event Settings Page (MATRIX Mode)
4
5
6
8
7
9
3
2
Each EVENT encompasses a single memory slot (1-32). For each event, the following
settings may be selected:
1.
Selects the
EVENT type
: ROUTE, BASE or BGM END (*See Glossary-Matrix)
2.
Selects the
input to be routed
(ROUTE EVENT Only)
3.
Indicates
Output Priority
(set in Channel Setting page)
4. Assigns how the event will be broadcast:
NONE (always active), VOX (audio
activated), *C1-12, *ZM module (control trigger)
5. Selects the output(s)
to which the signal will be routed.
6.
Indicates
type of trigger
7.
Assigns which of up to
4 events
are
contained in the BASE EVENT
. When the BASE
Event is activated, these assigned ROUTE Events will come online simultaneously
(Active for BASE EVENT only).
8. Assigns a control output
to activate a relay when the event is broadcast.
9.
Power On
assigns any EVENT to be the POWER ON default
. This usually a BASE
Event. LAST status may also be selected for Power On.
29