Make sure that you have turned off the AC power switch.
Connect the exchange, terminal boards and stations.
Are Data Transmitting and Receiving Units used?
Remove CP-63 from the exchange.
Set mini-Jumper (JP1) for battery from OFF to ON position.
Set function selection switches (SW-A ~ SW-E) for required functions.
Insert the CP-63 into the exchange.
Put all 4 "Link select" switches of the HC unit upward. (Link No. 15}
Switch on the exchange.
Look at indication of LINE ADDRESS of HC (14 LEDs) and SIGNAL
CODE indication (4 LEDs)
Memory is normal
Some errors in memory
ALL LED lamps are out
SIGNAL CODE indication
Lighted lamps of LINE ADDRESS
LEDs indicate erroneous MEMORY
ICs. See Section 3 (Page 13)
Place program switch on front panel of the CP in "ON" position.
Dial operation from station No. 200.
Initial programming of the exchange
Dial the Following:
*1
Dial tone will be heard
(Station No. 200 (100) becomes a programming station)
Confirmation tone will be heard. *2
(Clears function group S)
Confirmation tone will be heard. *2
(Clears function group A)
Confirmation tone will be heard. *2
(Clears function group B)
Confirmation tone will be heard
*2
(Clears function group C)
Confirmation tone will be heard. *2
(Clears function group D)
Confirmation tone will be heard. *2
(Clears function group E)
Confirmation tone will be heard. *2
(Clears personal numbers, single digit dial
numbers and remote numbers)
Program necessary functions (Refer to separate instructions for each function) *2
Place program switch on front panel of the CP in "OFF" position.
Dial operation from station No. 200.
*1
(Station No. 200 becomes a normal station.)
Note:
*1; The first station of each ex-
change becomes the program-
ming station:
Exchange "A" ... No. 200 (100)
Exchange "B" ... No. 470 (400)
Exchange "C" ... No. 740 (700)
*2; lf there is any error in CMOS
memory, you hear calling tone
instead of confirmation tone.
1. Connect Data Transmitting Unit (DT-
E11) and Data Receiving Unit (DR-
B61).
2. Set channel select switches (CHAN-
NEL SELECT) of DT-E11.
3. Set word select switches (WORD
SELECT) of DR-B61.
—12—
2. INITIAL CP-63 SET UP
In the event of the tie-line system, programming has to be set up in every exchange.