Temperature 

To check the temperature of the Mozart UV, tap the address set button and the 7- segment display will show the 
temperature. (For example: 28

 °C) 

 

 

Appendix

 

G

ENERAL 

M

AINTENANCE

 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage and 
environment are contributing factors in determining frequency.  As a general rule, fixtures should be cleaned at 
least twice a month.  Dust build up reduces light output performance and can cause overheating.  This can lead 
to reduced lamp life and increased mechanical wear. Be sure to disconnect power to the fixture before 
conducting maintenance. 

Unplug fixture from power.  Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components.  Clean all glass when the fixture is cold with a mild solution 
of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or 
tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze 
and lint. 

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize 
light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or 
particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.  Clean with soft cloth 
using normal glass cleaning fluid.  Always dry the parts carefully.  Clean the external optics at least every 20 
days. Clean the internal optics at least every 30 to 60 days. 

 

L

IMITED 

W

ARRANTY

 

Solaris LED fixtures (the Product) are warranted by TMB against defective materials or workmanship for a period 
of two (2) years from the date of original sale by TMB.  
 
TMB’s warranty shall be restricted to the repair or replacement of any part that proves to be defective and for 
which a claim is submitted to TMB before the expiration of the applicable warranty periods.  
 
This Limited Warranty is void if the defects of the Product are the result of:  
 

 

Opening the casing, repair, or adjustment by anyone other than TMB or persons specifically authorized by 
TMB  

 

Accident, physical abuse, mishandling, or misapplication of the product.  

 

Damage due to lightning, earthquake, flood, terrorism, war, or act of God.  

 
TMB will not assume responsibility for any labor expended, or materials used, to replace and/or repair the 
Product without TMB’s prior written authorization. Any repair of the Product in the field, and any associated labor 
charges, must be authorized in advance by TMB. Freight costs on warranty repairs are split 50/50: Customer 
pays to ship defective product to TMB; TMB pays to ship repaired product, ground freight, back to Customer.  
 

Содержание SOLARIS MOZART UV

Страница 1: ...MOZART UV USER MANUAL TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 Rev 1 1 081519 e mail techsupport tmb com...

Страница 2: ...ght great for low weight load bearing structures and surfaces Single cable simple power data connections for easy daisy chain applications Easy remote addressing and dual mode switching via RDM UNPACK...

Страница 3: ...rs yourself In the unlikely event your unit may require service please contact your distributor FUSE REPLACEMENT Mozart Drive PortableMount 4A 250V slow blow 5x20mm 0 2x0 8 in Mozart Drive RackMount 2...

Страница 4: ...tandard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterio...

Страница 5: ...ntensity Control 8bit Control Mozart Drive DC power 48 V Power Consumption 20 W or 40 W High Power mode Max fixtures Mozart Drive PortableMount 8 Standard mode 5 High Power mode Max fixtures Mozart Dr...

Страница 6: ...tor of the DMX console 2 Connect the opposite end of the cable female to the input connector of the Mozart Drive consisting of a male 5 pin connector 3 Proceed to connect from the Mozart Drive output...

Страница 7: ...ixtures 1 8 or 1 5 in High Power mode follow these steps 1 Press and hold Set Address button located at the back of the Mozart UV fixture 2 The current internal fixture ID will appear 1 8 3 To change...

Страница 8: ...e fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the part...

Страница 9: ...ust be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Please contact TMB and request RMA prior to shipping the fixture Be prepared...

Страница 10: ...Mozart UV 1 Power consumption 1x 200 W 4x 200 W Max cable length 328 ft 100 m per output with fixtures at any interval DMX connectors In Out XLR 5 pin M F Control power connecctors Out Amphenol Sensor...

Страница 11: ...Mozart Drive RackMount 2U...

Отзывы: