background image

TEG-Y8F-M-00   20 August 2013

 

 

10. Troubleshooting 

 

When troubleshooting the strainer, all safety rules should be strictly obeyed 

Fault

 

Possible reason

 

Remedy

 

No flow   

Flange dust caps were not removed  Remove dust caps from flanges   
Dirty screen   

Clean or replace the screen   

Poor flow 

 

 

Clogged pipeline   

Check the pipeline   

Broken connecting flange  Bolts tightened unevenly   

Replace the strainer with new one 

11. Disposal 

Obsolete and dismantled strainers must not be disposed of with household waste. This 
product is made of materials which can be re-used and should be delivered to 

esignated recycling centers. 

d

 

12. Product Warranty 

 

1. Warranty Period 

One year following product delivery. 

2. Warranty Coverage 

TLV Euro Engineering GmbH warrants this product to the original purchaser 
to be free from defective materials and workmanship. Under this warranty, 
the product will be repaired or replaced at our option, without charge for 
parts or labor. 

3.  This product warranty will not apply to cosmetic defects, nor to any product 

whose exterior has been damaged or defaced; nor does it apply in the 
following cases: 
1)  Malfunctions due to improper installation, use, handling, etc., by other 

than TLV Euro Engineering GmbH authorized service representatives. 

2)  Malfunctions due to dirt, scale, rust, etc. 
3)  Malfunctions due to improper disassembly and reassembly, or 

inadequate inspection and maintenance by other than TLV Euro 
Engineering GmbH authorized service representatives. 

4)  Malfunctions due to disasters or forces of nature. 
5)  Accidents or malfunctions due to any other cause beyond the control of 

TLV Euro Engineering GmbH. 

4.  Under no circumstances will TLV Euro Engineering GmbH be liable for 

consequential economic loss damage or consequential damage to property. 

*  *  *  *  *  *  *

 

For Service or Technical Assistance: 

Contact your 

 

representative or your regional

 

 office. 

 

 

Daimler-Benz-Straße 16-18, 74915 Waibstadt, 

Germany

 

Tel: [49]-(0)7263-9150-0    Fax: [49]-(0)7263-9150-50 

 

Star Lodge, Montpellier Drive, Cheltenham, Gloucestershire, GL50 1TY, 

U.K.

 

Tel: [44]-(0)1242-227223    Fax: [44]-(0)1242-223077 

 

Parc d’ Ariane 2, bât. C, 290 rue Ferdinand Perrier, 69800 Saint Priest, 

France

 

Tel: [33]-(0)4-72482222    Fax: [33]-(0)4-72482220

   

Содержание Y8F Series

Страница 1: ...TEG Y8F M 00 20 August 2013 Strainers Y8F Copyright 2013 by TLV Euro Engineering GmbH All rights reserved ...

Страница 2: ...duct is delivered before doing anything else check the specifications and external appearance to make sure nothing is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly If detailed instructions for special order specifications or options not contained in this manual are required please contact for full deta...

Страница 3: ...to the product or malfunctions that may lead to serious accidents Local regulations may restrict the use of this product to below the conditions quoted Take measures to prevent people from coming into direct contact with product outlets Failure to do so may result in burns or other injury from the discharge of fluids When disassembling or removing the product wait until the internal pressure equal...

Страница 4: ... damage or detach the meshed screen 1 Product Description Y strainers are provided with cast markings according to the requirements of the PN EN19 standard The markings facilitate technical identification and contain nominal diameter DN mm nominal pressure PN bar body and cover material arrow indicating medium flow direction manufacturer heat number CE marking for products subject to the 97 23 EC ...

Страница 5: ...is The strainer will remove solid particles which are larger than the size of the holes in the screen mesh In order to remove magnetic debris from the medium it is recommended to use a magnetic cartridge located in the centre of the filter screen The type of working medium may make some materials unsuitable for use Strainers are designed for normal working conditions Working pressure should be ada...

Страница 6: ...ne where the strainer is fitted should be arranged in such a way that the strainer body is not subjected to any bending or stretching forces Bolted joints on the pipeline must not cause additional stress resulting from excessive tightening and fastener materials must comply with the working conditions of the plant Install the strainer in such a way that flow direction matches that of the arrow pla...

Страница 7: ...between the body and the strainer cover The gasket contains a metal core which may cause injury Tighten the hexagon nuts of the cover bolts evenly and crosswise using a torque wrench In order to assure safe performance each strainer especially those that are rarely used should be surveyed on a regular basis Inspection frequency should be determined by the user but should not be less than once per ...

Страница 8: ...o cosmetic defects nor to any product whose exterior has been damaged or defaced nor does it apply in the following cases 1 Malfunctions due to improper installation use handling etc by other than TLV Euro Engineering GmbH authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or inadequate inspection and maintenance b...

Отзывы: