background image

 

172-65118MA-04  (T8N/TF8N/T10N/TF10N)    6  Oct  2021

 

5

 

Configuration 

 

T8N/TF8N 

(Optional Models: T8NL/TF8NL)

 

T10N/TF10N 

(Optional Models: T10NL/TF10NL)

 

 

 

 

No.  Name 

  No.  Name 

  No.  Name 

 

Body 

 

 

Ball 

   

Nameplate 

 

 

Sight Glass 

   

Gasket 

   

Guard Plate 

 

 

Glass Holder 

 

  R: Part included in repair kit; parts not available separately 

 

NOTE: Construction of the T10N/TF10N/T10NL/TF10NL differs from that of the 

T8N/TF8N/T8NL/TF8NL only in that there is a through-hole in the partition between 
the inlet and outlet, making them suitable for use with large flow rates. 

 

Installation 

 

 

As glass parts will wear and deteriorate in quality, they should be 

replaced annually. If the glass becomes damaged, subsequent fluid 

discharge could result in injury or other damage.

 

WARNING 

 

 

Install properly and DO NOT use this product outside the recommended 

operating pressure, temperature and other specification ranges. 

Improper use may result in such hazards as damage to the product or 

malfunctions which may lead to serious accidents. Local regulations 

may restrict the use of this product to below the conditions quoted.

 

CAUTION 

 

 

Take measures to prevent people from coming into direct contact with 

product outlets. Failure to do so may result in burns or other injury from 

the discharge of fluids.

 

CAUTION 

 

 

Do not use excessive force when connecting threaded pipes to the 

product. Over-tightening may cause breakage leading to fluid 

discharge, which may cause burns or other injury.

 

CAUTION 

Installation, inspection, maintenance, repairs, disassembly, adjustment and valve 
opening/closing should be carried out only by trained maintenance personnel. 
1.  Before installation, be sure to remove all protective seals. 
2.  Before installing the product, open the inlet valve and blow out the piping to 

remove any piping scraps, dirt and oil. Close the inlet valve after blowdown. 

3.  Install the product so the arrow on the body is pointing in the direction of flow. 
4.  Install on horizontal piping with the glass portion facing up. 
5.  Open the inlet valve and check to make sure that the product functions properly. 
6.  As sight glasses deteriorate with use, they should be replaced annually to ensure 

safety. 

If there is a problem, determine the c

ause using the “Troubleshooting” section in this 

manual.

 

Содержание T10N

Страница 1: ...172 65118MA 04 T8N TF8N T10N TF10N 6 October 2021 Sight Glass T8N TF8N T10N TF10N Optional Models T8NL TF8NL T10NL TF10NL Copyright 2021 by TLV CO LTD All rights reserved...

Страница 2: ...to make sure nothing is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly This sight glass is for installat...

Страница 3: ...poses a threat of death or serious injury Indicates that there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment product damage As glass par...

Страница 4: ...in any way Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids Use only under conditions in which no freeze...

Страница 5: ...tside the recommended operating pressure temperature and other specification ranges Improper use may result in such hazards as damage to the product or malfunctions which may lead to serious accidents...

Страница 6: ...estrict the use of this product to below the conditions quoted CAUTION Take measures to prevent people from coming into direct contact with product outlets Failure to do so may result in burns or othe...

Страница 7: ...l inspection of the following items should be done on a daily basis to determine whether the product is operating properly or has failed Periodically at least biannually the operation should also be c...

Страница 8: ...Part During Disassembly During Reassembly Glass Holder Remove with a wrench Consult the table of tightening torques and tighten to the proper torque Gasket Remove the gasket and clean sealing surfaces...

Страница 9: ...172 65118MA 04 T8N TF8N T10N TF10N 6 Oct 2021 8 Exploded View Glass Holder Sight Glass Gasket Body Gasket Guard Plate Ball...

Страница 10: ...ard plate is dirty Clean the guard plate There is an build up of dirt inside the body Clean Leaks to the outside of the product Deterioration or damage to gaskets Replace with new gaskets Improper gla...

Страница 11: ...ause beyond the control of TLV TII or TLV group companies or 6 improper storage maintenance or repair or 7 operation of the Products not in accordance with instructions issued with the Products or wit...

Страница 12: ...OF DISASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT INJURY TO OTHER PROPERTY DAMAGE TO BUYER S OR THE FIRST END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHE...

Страница 13: ...oks Road Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao...