34
Drive Section Troubleshooting
The drive section has a built-in microcomputer that has a self-diagnosis function of the
malfunction of the drive section.
Identify the cause of faulty by following procedures shown below.
1. Turn OFF the power (supplying) to the drive section.
2. Remove the motor cover (blue housing) of the drive section.
3. Confirm the position of the 4 LEDs (LE1 – 4) and the switch (PS1) mounted on
the board from the terminal block side.
4. Turn ON the power supply to the drive section, being careful not to be
electrocuted or cause a short out since the electrical circuit is exposed.
5. Press the PS1 switch. Confirm the lighting status of the 4 LEDs. Different LEDs
light up depending on the malfunction. Refer to the table on the next page and
take proper measures.
172-65185A-08 (MC-COSR Multi-control Valve) 20 Nov 2014