Disassembly/Reassembly
Warning
NEVER apply direct heat to the float. The float may explode due to increased internal pressure,
causing accidents leading to serious injury or damage to property and equipment.
Caution
Use hoisting equipment for heavy objects (weighing approximately 20 kg (44 lb) or more).
Failure to do so may result in back strain or other injury if the object should fall.
Use the eye bolts for removing the cover only; DO NOT use the eye bolts for hoisting the
product. Eye bolts may break under strain, possibly resulting in serious injury.
When disassembling or removing the product, wait until the internal pressure equals
atmospheric pressure and the surface of the product has cooled to room temperature.
Disassembling or removing the product when it is hot or under pressure may lead to discharge of
fluids, causing burns, other injuries or damage.
Use the following procedures to remove components. Use the same procedures in reverse to
reassemble. (Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.)
Drain Plug
Part Name
During Disassembly
During Reassembly
Drain Plug 28
Remove with a socket wrench
Consult the table of tightening torques
and tighten to the proper torque
Drain Plug
Gasket 27
Remove the gasket and clean sealing
surfaces
Replace with a new gasket; coat
surfaces with anti-seize
Detaching/Reattaching the Cover
Part Name
During Disassembly
During Reassembly
Cover Nut 12
Remove with a socket wrench
Consult the table of tightening torques
and tighten to the proper torque
Cover 2
Use all four (4) eye bolts to lift up and
off, making sure to evenly distribute
the weight of the cover among them
Make sure there are no pieces of the
old gasket left on the sealing surfaces
of the body and cover, align the arrows
on the body and cover and reattach
Cover Gasket 10
Remove the gasket and clean sealing
surfaces
Replace with a new gasket
Disassembly/Reassembly of the X-element Case and Components Inside the
X-element Case
Part Name
During Disassembly
During Reassembly
X-element Case
16
Remove with a box wrench
Consult the table of tightening torques
and tighten to the proper torque
X-element Case
Gasket 22
Remove the gasket and clean sealing
surfaces
Replace with a new gasket; coat
surfaces with anti-seize
Snap Ring 17
(X-element Case
16)
Pinch the insides together and remove
from the X-element case
Insert securely into the guide in the
X-element case
15