background image

 

 

172-65450MA-06  (JH5SL-P/JH5SH-P)    8  Nov  2021 

1

 

Contents

 

Introduction ....................................................................... 1

 

Checking the Piping .......................................................... 4

 

Operation .......................................................................... 5

 

Specifications .................................................................... 6

 

Configuration ..................................................................... 6

 

Installation ......................................................................... 7

 

Maintenance ...................................................................... 8

 

Disassembly/Reassembly ................................................. 9

 

Instructions for Plug/Holder Disassembly and Reassembly ... 12

 

Troubleshooting .............................................................. 13

 

TLV EXPRESS LIMITED WARRANTY ........................... 14

 

Service ............................................................................ 16

 

Options ............................................................................ 17

 

 

Introduction 

Thank you for purchasing the TLV free float steam trap. 

This product has been thoroughly inspected before being shipped from the factory. 
When the product is delivered, before doing anything else, check the specifications and 
external appearance to make sure nothing is out of the ordinary. Also be sure to read 
this manual carefully before use and follow the instructions to be sure of using the 
product properly. 

This instruction manual is edited based on the JH-P Series (with cover plug). The JH-W 
Series (with socket welded cover connection), JH-F Series (with flanged cover 
connection) and JH-V Series (with manual air vent valve) are described at the end of this 
manual in the 'Option

’ section.   

This  free  float  steam  trap  employs  a  hinge-less  and  lever-less  free  float  to  rapidly, 
automatically  and  continuously  discharge  the  inflowing  condensate  that  is  continuously 
generated  inside  the  equipment,  thus  preventing  the  accumulation  of  condensate  and 
thereby improving the heat transfer efficiency of the equipment. 

This  steam  trap  also  employs  a  precision-ground  float  and  three-point  seating  that 
supports  the  float  securely  at  three  points  and  ensures  a  high  degree  of  sealing  when 
even only minute quantities of condensate are present. 

This free float steam trap is suitable for applications with the introduction of almost no air 
(such as process systems and steam-using equipment under long continuous operation, 
or superheated and saturated steam mains, branches and trace lines). 

If detailed instructions for special order specifications or options not contained in this 
manual are required, please contact TLV for full details. 

This instruction manual is intended for use with the model(s) listed on the front cover. It 
is necessary not only for installation but for subsequent maintenance, 
disassembly/reassembly and troubleshooting. Please keep it in a safe place for future 
reference.

Содержание JH5SH-F

Страница 1: ...172 65450MA 06 JH5SL P JH5SH P 8 November 2021 Free Float Steam Trap JH5SL P JH5SH P Optional Models JH5SL W JH5SL F JH5SL V JH5SH W JH5SH F JH5SH V Copyright 2021 by TLV CO LTD All rights reserved ...

Страница 2: ...e Option section This free float steam trap employs a hinge less and lever less free float to rapidly automatically and continuously discharge the inflowing condensate that is continuously generated inside the equipment thus preventing the accumulation of condensate and thereby improving the heat transfer efficiency of the equipment This steam trap also employs a precision ground float and three p...

Страница 3: ...h poses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage WARNING NEVER apply direct heat to the float The float may explode due to increased internal pressure causing accidents leading to serious injury or damage to property and equipment CAUTION Inst...

Страница 4: ...the recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids Use only under conditions in which no freeze up will occur Freezing may damage the product leading to fluid discharge which may cause burns or other i...

Страница 5: ...re has a check valve TLV CK been installed 5 Is a bypass valve installed 6 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the product 7 Has the piping work been done correctly as shown in the figures below Requirement Correct Incorrect Install catchpot with the proper diameter Diameter is too small Make sure the flow o...

Страница 6: ...Discharge of Large Quantities of Condensate Increases in the condensate inflow rate cause the condensate level in the trap to rise The float consequently rises and enlarges the opening of the orifice A allowing more condensate to be discharged In this manner continuous condensate discharge occurs while the opening size of the orifice varies depending on the condensate flow rate 3 Closed Position W...

Страница 7: ...ch may cause burns or other injury CAUTION Refer to the product nameplate for detailed specifications Model Maximum Allowable Temperature TMA Maximum Allowable Pressure Nominal Diameter Maximum Differential Pressure Production Lot No Valve No Maximum Operating Temperature Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITI...

Страница 8: ...pection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before installation be sure to remove all protective seals 2 Before installing the product open the inlet valve and blow out the piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Install the product so the arrow on the body ...

Страница 9: ...tinuously together with flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The product is quiet and makes no noise and the surface temperature of the product is low Blowing Live steam continually flows from the outlet and there is a continuous metallic sound Steam Leakage Live s...

Страница 10: ...per torque Cover Remove being careful not to scratch the gasket sealing surfaces Make sure there are no pieces of the old gasket left on the sealing surfaces of the body and cover align the arrows on the body and cover and reattach Cover Gasket Remove the gasket and clean sealing surfaces Replace with a new gasket Cover Plug Remove with a socket wrench Consult the table of tightening torques and t...

Страница 11: ...e 140 100 17 21 32 Orifice Plug 180 130 38 11 2 Cover Nut JH5SL P 160 115 22 7 8 Cover Nut JH5SH P 170 125 24 15 16 Cover Plug 100 73 26 1 NOTE Coat all threaded portions with anti seize If drawings or other special documentation were supplied for the product any torque given there takes precedence over values shown here 1 N m 10 kg cm ...

Страница 12: ...450MA 06 JH5SL P JH5SH P 8 Nov 2021 11 Exploded View Cover Plug Cover Plug Gasket Cover Nut Cover Cover Gasket Screen Float Cover Float Cover Bolt Body Orifice Plug Orifice Gasket Orifice Orifice Plug Gasket ...

Страница 13: ...face of the plug holder making sure the anti seize affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads Hold the plug holder upside down to make sure that the anti seize makes the gasket stick to the plug holder even when the plug holder is held upside down Screw the plug holder by hand into the product body while making sure that...

Страница 14: ...n the trap inlet and outlet Compare specifications and actual operating conditions Steam locking has occurred Perform a bypass blowdown or close the trap inlet valve and allow the trap to cool Air binding has occurred Perform a bypass blowdown or consider switching to a product with a built in air vent or air vent valve Steam is discharged or leaks from the outlet blowing steam leakage Clogged ori...

Страница 15: ... Products not in accordance with instructions issued with the Products or with accepted industry practices or 8 use for a purpose or in a manner for which the Products were not intended or 9 use of the Products in a manner inconsistent with the Specifications or 10 use of the Products with Hazardous Fluids fluids other than steam air water nitrogen carbon dioxide and inert gases helium neon argon ...

Страница 16: ...ODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMMERCIAL LOSSES WHERE DUE TO OPERATION OF LAW CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY UNDER ANY OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED WARRANTY NOT NEGATED HEREBY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE CANNOT BE EXCLUDED SUCH DA...

Страница 17: ...ks Road Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao Bao Road Shanghai China 200233 Tel Fax 86 0 21 6482 8622 86 0 21 6482 8623 No 16 Jalan MJ14 Taman Industri Meranti Jaya 47120 Puchong Selangor Malaysia Tel Fax 60 3 8065 2928 60 3 8065 2923 252 94 K L ...

Страница 18: ... automatically discharge inflowing condensate However if low temperature condensate in the piping blocks the trap inlet passage displacement inside the piping of steam by condensate is obstructed and condensate can no longer flow into the trap steam locking Traps only function in the presence of condensate inflow A pressure balancing line prevents the occurrence of steam locking Install the pressu...

Страница 19: ...valve and take care to avoid being burned by hot air or steam blowing from the vent The exhaust port is a 2 mm 1 16 diameter hole on the side of the air vent valve body DO NOT under any circumstances allow any unprotected part of your body to come in front of this hole 2 Never leave an open air vent valve unattended Tools required 1 open end wrench distance across flats 17 mm 21 32 2 long handled ...

Страница 20: ... binding Air binding may also occur during the normal course of trap operation due to the slow accumulation of air inside the trap The air vent valve on the top of this trap is to be operated only when air binding has occurred Follow the instructions in the earlier part of this section to operate the air vent valve and release the air accumulated inside the trap The air vent valve is to be open on...

Отзывы: