background image

172-65606A-02 (JAH5RA-R/JAH7RA-R)    12 January 2021 

 

 

 

 

Manufacturer 

 

 

881 Nagasuna, Noguchi, Kakogawa, Hyogo, 675-8511 Japan 

Tel: [81]-(0)79-422-1122    Fax: [81]-(0)79-422-0112 

 

Copyright © 2021 by TLV CO., LTD. All rights reserved 

 

Free Float Drain Trap   

JAH5RA-R 
JAH7RA-R 

 

Introduction 

Thank you for purchasing the TLV free float drain trap. 

This product has been thoroughly inspected before being shipped from the factory. 
When the product is delivered, before doing anything else, check the specifications 
and external appearance to make sure nothing is out of the ordinary. Also be sure to 
read this manual carefully before use and follow the instructions to be sure of using 
the product properly. 

This product is designed, manufactured, and inspected for use with air, inert 
gases and condensate. Do not use for toxic, flammable or otherwise 
hazardous fluids. Hereafter in this manual, the words 

“gas” and “gases” 

should be read as 

“inert gas” and “inert gases”. 

This free float drain trap employs a precision-ground float and three-point seat. With no 
hinges or levers, the trap automatically and continuously discharges condensate as it 
forms in the air/gas system, preventing it from backing up in the system. The three-
point seat supports the precision-ground float at three points, ensuring an air-tight seal 
even under extremely low condensate loads. This free float drain trap is also inline 
repairable, facilitating repair and maintenance, resulting in considerable time savings. 

If detailed instructions for special order specifications or options not contained in this 
manual are required, please contact TLV for full details. 

This instruction manual is intended for use with the model(s) listed on the front cover. 
It is necessary not only for installation but for subsequent maintenance, 
disassembly/reassembly and troubleshooting. Please keep it in a safe place for 
future reference. 
 

Содержание JAH5RA-R

Страница 1: ...fluids Hereafter in this manual the words gas and gases should be read as inert gas and inert gases This free float drain trap employs a precision ground float and three point seat With no hinges or levers the trap automatically and continuously discharges condensate as it forms in the air gas system preventing it from backing up in the system The three point seat supports the precision ground flo...

Страница 2: ...sure safety and prevent equipment damage and personal injury For situations that may occur as a result of erroneous handling three different types of cautionary items are used to indicate the degree of urgency and the scale of potential damage and danger DANGER WARNING and CAUTION The three types of cautionary items above are very important for safety be sure to observe all of them as they relate ...

Страница 3: ...sting equipment for heavy objects weighing approximately 20 kg 44 lb or more Failure to do so may result in back strain or other injury if the object should fall Take measures to prevent people from coming into direct contact with product outlets Failure to do so may result in burns or other injury from the discharge of fluids When disassembling or removing the product wait until the internal pres...

Страница 4: ... to be installed horizontal 3 Has sufficient space been secured for maintenance 4 Have isolation valves been installed at the inlet and outlet If the outlet is subject to back pressure has a check valve been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Has the piping work been done correctly as...

Страница 5: ...usemayresult insuchhazards as damagetotheproduct or malfunctions whichmayleadtoserious accidents Local regulations mayrestrict theuseof this product tobelowtheconditions quoted CAUTION DONOT usethisproduct inexcessof themaximumoperatingpressure differential suchusecouldmakedischargeimpossible blocked CAUTION Useonlyunder conditions inwhichnofreeze upwill occur Freezing maydamagetheproduct leadingt...

Страница 6: ...ice 10 Cover Bolt 16 Drain Plug Gasket 5 Valve Seat Orifice Gasket 11 Cover Nut 17 Drain Plug 6 Valve Seat Orifice Plug 12 Cover Gasket Option JAH7RA R Rubber valve seat For pressure balancing Line G PF 3 8 No Name 1 Body 2 Cover 3 Float 4 Valve Seat Orifice 5 Valve Seat Orifice Gasket 6 Valve Seat Orifice Plug 7 Valve Seat Orifice Plug Gasket 8 Screen 9 Flange Socket 10 Cover Bolt 11 Cover Nut 12...

Страница 7: ... carried out only by trained maintenance personnel 1 Before installation be sure to remove all protective seals 2 Before installing the product open the inlet valve and blow out the piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Install the product so the arrow on the body is pointing in the direction of flow 4 The product should be inclined no more than 5 h...

Страница 8: ... condensate and thus preventing condensate from entering the trap This phenomena is called air binding Air binding occurs more often in piping with long horizontal lengths smaller diameters or multiple bends To prevent air binding and ensure air or gas can be displaced by incoming condensate a pressure balancing line should be installed between the trap cover and the dry portion of the receiver ta...

Страница 9: ... should fail it may cause damage to piping and equipment resulting in faulty or low quality products or losses due to air or gas leakage Normal Condensate is discharged continuously and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged Blowing Air or gas continually flows from the outlet and t...

Страница 10: ...et piping pressure balancing line condensate discharge piping etc Part During Disassembly During Reassembly Cover Nut Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Cover Remove by lifting up and off Align the arrows on the body and cover and reattach Cover Gasket Remove the gasket and clean sealing surfaces on the body and cover Replace with a...

Страница 11: ...d the product body using a rag and or cleaning agents then check to make sure the surfaces are not scratched or deformed 4 Coat both the gasket surface of the plug holder and the threads of the plug holder with anti seize then press the gasket onto the center of the gasket surface of the plug holder making sure the anti seize affixes the gasket tightly to the plug holder Check to make sure the gas...

Страница 12: ...t Cover Nut Cover Valve Seat Valve Seat Plug Gasket Valve Seat Plug Valve Seat Gasket Drain Plug Gasket Option Drain Plug Option Nameplate Body JAH7RA R Screen Float Cover Bolt Body Valve Seat Valve Seat Plug Gasket Valve Seat Plug Valve Seat Gasket Drain Plug Gasket Drain Plug Balancing line Plug Balancing line Plug Gasket Cover Nut Cover Cover Gasket ...

Страница 13: ...d make sure it has not become dislodged or is not incorrectly installed The trap operating pressure exceeds the maximum specified pressure or whether there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions The specific gravity of the fluid is not suitable for this product Consult TLV Air gas is discharged or leaks from th...

Страница 14: ...s in a manner inconsistent with the Specifications or 10 use of the Products with Hazardous Fluids fluids other than steam air water nitrogen carbon dioxide and inert gases helium neon argon krypton xenon and radon or 11 failure to follow the instructions contained in the TLV Instruction Manual for the Product Duration of Warranty This warranty is effective for a period of the earlier of i three 3...

Страница 15: ...END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMMERCIAL LOSSES WHERE DUE TO OPERATION OF LAW CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY UNDER ANY OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED WARRANTY NOT NEGATED HEREBY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE CANNOT BE EXC...

Страница 16: ...ons for Area A JAH5RA R JAH7RA R Standard without drain plug Standard with G PF drain plug With G PF Drain Plug With R PT or NPT Drain Plug Without Drain Plug With R PT or NPT Drain Plug Options for Area B Balancing Line Plug with Tapered Thread Option JAH5RA R Standard with G PF plug With R PT or NPT Plug Socket Flange JAH7RA R Standard with G PF plug With R PT or NPT Plug Socket Flange ...

Отзывы: