9
4. Spacer Installation
If spacing adjustment is
necessary to accommodate
installation, install a spacer on
the outlet flange.
The spacer should consist of a
spacer, gaskets, bolts and nuts.
Fit gaskets to both sides of the
spacer between the
PN-COS-
16
outlet and the pipe flange.
Fasten with bolts and nuts.
Correct
spacer
location
Incorrect
spacer
location
5. Piping Support
Install the
PN-COS-16
, paying
attention to avoid excessive
load, bending and vibration.
Support the inlet and outlet
pipes securely.
6. Maintenance Space
Leave sufficient space for maintenance, inspection
and repair.
(Unit: mm (in))
200
(8)
200 (8)
150
(6)
100 (4)
150
(6)
200
(8)
7. Trap Outlet Pipe
For ease of maintenance, installation of
a union connection is recommended for
the trap outlet pipe.
Connect the outlet pipe to a condensate
return line, or extend it to a trench. In the
case of the latter, make sure the end of
the pipe is above the waterline. (Dirt and
water may be sucked up by the vacuum
formed during trap closure and system
shutdown.)
Small Hole
172-65588MA-02 (
PN-COS