the overcurrent (magnetothermal, maximum 15A). It must be very quickly recognizable
and readily accessible. A suitable blow fuse must also be installed for protection.
For connection to the mains, use a multipolar cable having minimum 3x1,5 mm2 (15
AWG). The main cable must be at least protected by an ordinary PVC sheath.
Fasten all the cables inside the housing with cables ties or other fixing means to avoid
the electrical contact with surrounding parts in case that terminal blocks screw off.
Electrical connections (such as plugs and cords) must be protected from potential
hazardous environmental factors (e.g. foot traffic, hitting objects).
Ensure that the unit case is properly earthed, connecting all the earth ground studs.
Earth cable should be about 10mm longer than the other cables on the connector, in
such way that it won't be accidentally disconnected if the cable is stretched or pulled.
When leaving the unit unused for long periods, disconnect supply cables.