TABLE OF CONTENTS

Descriptions and Specifications.......................................................................................................................................1
Installation Restrictions....................................................................................................................................................1
Cautions .......................................................................................................................................................................1-2
Recommended Methods and Patterns of Operation....................................................................................................2-3
Recommended Installation and Termination Locations................................................................................................3-4
X

CHANGE

R

TM

Installation ..............................................................................................................................................4-6

Maintenance ....................................................................................................................................................................6
How to Obtain Service & Warranty ..............................................................................................................................6-7
Replacement Parts & Accessories ..................................................................................................................................7

X

CHANGE

R

TM

is a trademark of Tjernlund Products, Inc. 

Tjernlund Products welcomes your comments and questions.  Call us at (651) 426-2993, (800) 255-4208, Fax (651) 426-9547, email us
at [email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.

DESCRIPTION

The X

CHANGE

R

TM

model X2R is a dual fan mechanical ventilator capable of exhausting inside air, providing fresh outside air or provid-

ing a balanced air exchange. The fans can be independently switched on or off or be easily reversed to provide fresh outside air or
exhaust inside air. The X

CHANGE

R

TM

can be operated by a standard plug-in timer or Tjernlund’s optional DH2P dehumidistat control

which operates the fan(s) based on the relative humidity sensed inside the home. The DH2P control includes an “On” setting that will
operate the fan(s) continuously or it can be turned “Off” so the fan(s) do not operate during undesirable seasons.Tjernlund’s optional
SCP speed control kit is also available to vary speed of fans if desired. See accessories on page 7.   

X2R SPECIFICATIONS

GENERAL INFORMATION

Each X

CHANGE

R

TM

is electrically factory line tested before shipment. After opening carton, Inspect thoroughly for hidden damage. 

INSTALLATION RESTRICTIONS

WARNING:

Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to 

this manual. For assistance or additional information consult a qualified installer, service agency or the equipment supplier.

WARNING:

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and 

Air Conditioning Engineers (ASHRAE), and the local code authorities. 

WARNING:

Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed

combustion. Carbon monoxide poisoning may result. Use the DT2-6 6” duct take-off kit so exhaust can be removed from 
outside the mechanical room if necessary.

Observe proper location of hood as described on page 3. The X

CHANGE

R

TM

must only be installed with the hood on an exterior wall.

Do not discharge intake air onto water pipes or other equipment which may be affected by temperature extremes.

CAUTIONS

WARNING: 

Failure to install, maintain and/or operate the X

CHANGE

R

TM

in accordance with manufacturer’s instructions may result in 

conditions that can produce bodily injury and property damage.

MODEL X2R XCHANGER

Rough-in Wall Opening Dimensions:  

13 1/4” x 6 1/2” Oval opening - utilize included template

8061034

FLEXIBLE TUBING

NOMINAL 6" DIAMETER

BY INSTALLER

1 FAN

2 FANS

Voltage

120

120

Watts

20

40

Amps

0.3

0.6

CFM

90

180

Содержание XCHANGER X2R

Страница 1: ... reserved P N 8504202 THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE XCHANGER REV A 07 14 TJERNLUND PRODUCTS INC 1601 Ninth Street White Bear Lake MN 55110 6794 PHONE 800 255 4208 651 426 2993 FAX 651 426 9547 Visit our web site www tjernlund com ...

Страница 2: ...ing carton Inspect thoroughly for hidden damage INSTALLATION RESTRICTIONS WARNING Improper installation adjustment alterations service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the equipment supplier WARNING Sufficient air is needed for proper combustion and exhausting of gases th...

Страница 3: ... or needs of the occupants For example a family with smok ers may want to cycle the XCHANGERTM more frequently than a family of non smokers Another timed method may be to cycle the XCHANGERTM during peak usage of exhaust fans such as bathroom kitchen laundry or utility Outdoor air should be brought in at these peak times to help balance out pressure inside the house The XCHANGERTM can be cycled on...

Страница 4: ...t exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed combustion Carbon monoxide poisoning may result Use the optional DT2 6 6 duct take off kit so exhaust can be removed from outside the mechanical room if necessary It is required that the XCHANGERTM be installed in a location where it will not be directed at the occupants Do not discharge...

Страница 5: ...t damage electrical wiring and other hidden utilities Using a 1 2 bit drill pilot holes noted on the template from inside through rim joist wall board siding etc keeping drill bit perpendicular to the wall 1 2 bit must be long enough to penetrate through exterior 3 Use a level to mark 4 holes drilled in step 2 and connect the holes on building exterior See Diagram C Use provided X2R oval template ...

Страница 6: ... 16 x 1 1 4 screws on left right and center mounting feet See Diagram K 11 Use 6 flex duct to connect XCHANGERTM hood to fan assembly collars Firmly secure duct to collars with included zip ties Insulated flex should be used in cold climates to prevent condensation Properly support duct to minimize sagging bends and sharp turns that may restrict air flow See Diagram L 5 DIAGRAM E DIAGRAM F LEVEL X...

Страница 7: ... was performed 4 Details of the problem LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products Inc warrants the components of the XCHANGERTM for one year from date of installation This warranty covers defects in material and workmanship This warranty does not cover normal maintenance transportation or installation charges for replacement parts or any other service calls or repairs This warr...

Страница 8: ...pairing or replacing at our option any product which shall within the above stated warranty period be returned to Tjernlund Products Inc at the address listed below postage prepaid THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF AND TJERNLUND PRODUCTS INC EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT THIS W...

Отзывы: