Installation Manual – THH

Redefine your comfort zone. ™ | www.titus-hvac.com

THH HIGH PERFORMANCE HORIZONTAL
FAN COIL UNITS

Section 1 - Receipt & Initial Installation

CODE COMPLIANCE

This equipment has been manufactured and certified in accordance with 

UL 1995-Standard for Safety, Heating and Cooling Equipment (CAN/CSA 

C22.2 NO 236- M90) and bears the Electrical Testing Laboratories (ETL) 

Mark under ETL File No: 3036742-002. 

RECEIPT AND INITIAL INSTALLATION 

No attempt should be made to handle, install, or service 

any unit without following safe practices regarding 

mechanical equipment.

 

All power must be disconnected before any installation or service 

should be attempted. More than one power source may be supplied to 

a unit. Power to remote mounted control devices may not be supplied 

through the unit. Never wear bulky or loose fitting clothing when 

working on any mechanical equipment. Gloves should only be worn 

when required for proper protection from heat or other possible injury. 

Safety glasses or goggles should always be worn when drilling, cutting, 

or working with chemicals such as refrigerants or lubricants. 

 

 

Never pressurize any equipment beyond specified operating 

 

pressures. Always pressure test with an inert fluid or gas such as 

clear water or dry nitrogen to avoid possible damage or injury in the 

event of a leak or component failure during testing.

 

Always protect adjacent flammable material when welding or 

 

soldering. Use suitable heat shield material to contain sparks or 

drops of solder. Have fire extinguisher available for use when welding  

or brazing. 

 

 

The manufacturer assumes no responsibility for personal injury or 

property damage resulting from improper or unsafe practices during 

the handling, installation, service, or operation of any equipment.

 

warning

UNPACKING & INSPECTION

All units are carefully inspected at the factory throughout the 
manufacturing process under a strict detailed quality assurance program, 
and where possible, all major components and subassemblies are carefully 
tested for proper operation and verified to be in full compliance with the 
factory manufacturing documents. Customer furnished components such 
as control valves, switches and DDC controls are not factory tested.

Each unit is carefully packaged for shipment to avoid damage during 
normal transport and handling. The equipment should always be stored in 
a dry place in the proper orientation as marked on the carton.

All shipments are made F.O.B. factory and it is the responsibility of the 
receiving party to inspect the equipment upon arrival. Any obvious  
damage to the carton and/or its contents should be recorded on the bill of 
lading and a claim should be filed with the freight carrier.

After determining the condition of the carton exterior,carefully remove  
each unit from the carton and inspect for hidden damage. At this time  
check to make sure that “furnished only” items such as switches, 
thermostats, etc. are accounted for. Any hidden damage should be 
recorded and immediately reported to the carrier and a claim filed as 
before. In the event a claim for shipping damage is filed, the unit, shipping 
carton, and all packing must be retained for physical inspection by the 
freight carrier. All equipment should be stored in the factory shipping 
carton with internal packing in place until installation.

At the time of receipt, the equipment type and arrangement should be 
verified against the order documents. Should any discrepancy be found, 
the local Sales Representative should be notified immediately so that the 
proper action may be instituted. Should any question arise concerning 
warranty repairs, the factory must be notified BEFORE any corrective 
action is taken. Where local repairs or alterations can be accomplished, 
the factory must be fully informed as to the extent and expected cost of 
those repairs before work is begun. Where factory operations are required, 
the factory must be contacted for authorization to return equipment 
and a Return Authorization Number will be issued. Unauthorized return 
shipments of equipment and shipments not marked with an authorization 
number will be refused. In addition, the manufacturer will not accept any 
claims for unauthorized expenses.

Содержание THH Series

Страница 1: ...Redefine your comfort zone www titus hvac com THH HIGH PERFORMANCE HORIZONTAL FAN COIL UNITS INSTALLATION MANUAL...

Страница 2: ...9 Model THHC Free Return Dimensions 20 Model THHC Free Return Unit Specific Dimensions 21 Model THHP Plenum Return Dimensions 22 Model THHP Plenum Return Unit Specific Dimensions 23 THHE Exposed Cabin...

Страница 3: ...all power and control circuits prior to servicing to avoid serious crushing or dismemberment injuries HOT PARTS HAZARDS Electric Resistance heating elements must be disconnected prior to servicing El...

Страница 4: ...lly tested for proper operation and verified to be in full compliance with the factory manufacturing documents Customer furnished components such as control valves switches and DDC controls are not fa...

Страница 5: ...ties are void if foreign material is allowed to be deposited on the motor or blower wheels of any unit Some units and or job conditions may require some form of temporary covering during construction...

Страница 6: ...ction of moisture into the system In the event that leaking or defective components are discovered the Sales Representative must be notified BEFORE any repairs are attempted All leaks should be repair...

Страница 7: ...eplace the filter s as described above Section 1 Receipt Initial Installation FAN REMOVAL This fan assembly is easily removable by unscrewing the 4 E 20 nuts from the fan deck and sliding the fan asse...

Страница 8: ...are subjected to a high temperature which may damage seals or other materials Many two position electric control valves depending on valve operation are provided with a manual opening lever This leve...

Страница 9: ...lation by either the factory or the controls contractor should be located and checked for proper function and compatibility All internal components should be checked for shipping damage and all electr...

Страница 10: ...er duct work attached supply and return grilles in place and all access doors and panels in place and secure A clean filter of the proper size and type must also be installed Failure to do so could re...

Страница 11: ...0 7 08 High 1 1 4 1 1 3 1 3 8 5 0 13 2 1 6 2 8 5 9 1 3 2 6 5 4 Medium 1 1 6 3 3 1 0 0 8 Low 1 1 8 2 6 0 8 0 7 10 High 1 1 4 1 1 3 1 4 9 5 0 13 2 2 2 2 8 5 9 1 9 2 6 5 4 Medium 1 1 5 4 1 1 5 1 2 Low 1...

Страница 12: ...2900 6 0 2 2 470 THHC THHP 12 4 10 1400 43000 31800 8 7 4 2 560 THHC THHP 14 4 10 1750 47100 36250 9 6 3 0 715 THHC THHP 16 4 10 2000 51000 41000 10 5 2 0 830 THHC THHP 18 4 10 2200 53000 42000 11 0 2...

Страница 13: ...oticeable water noise or undesired valve operation due to incorrect system pressures After the entire system is balanced these conditions will not exist on properly designed systems CONTROLS OPERATION...

Страница 14: ...fan disconnect the motor wire leads loosen the set screw on the motor shaft and remove the 3 cap screws that attached the motor to the blower housing To reassemble insert the motor into the blower whe...

Страница 15: ...14 6 14 6 16 7 17 8 2 Row Dry 11 5 13 6 14 6 16 7 20 9 20 9 22 10 24 11 2 Row Wet 14 6 18 8 20 9 23 10 27 12 28 13 32 15 35 16 3 Row Dry 16 7 19 9 21 10 24 11 30 13 30 14 33 15 36 16 3 Row Wet 21 10...

Страница 16: ...al type and number of controls provided on each unit The integrity of all electrical connections should be verified at least twice during the first year of operation Afterwards all controls should be...

Страница 17: ...43 5 208 19 2 24 1 28 9 33 7 38 5 43 3 230 17 4 21 8 26 1 30 5 34 8 39 2 277 14 4 18 1 21 7 25 3 28 9 32 5 14 115 34 8 43 5 208 19 2 24 1 28 9 33 7 38 5 43 3 48 1 230 17 4 21 8 26 1 30 5 34 8 39 2 43...

Страница 18: ...ring the cooling season to maintain a free flowing condensate Should the growth of algae and or bacteria be a concern consult an air conditioning and refrigeration supply organization familiar with lo...

Страница 19: ...mplete unit model number 2 Unit hand connection right or left hand while facing the direction of airflow at the inlet 3 Complete part description including any numbers On warranty replacements in addi...

Страница 20: ...rd side mounted enclosure and includes 2 additional knockouts on bottom of unit on left side 3 Standard externally foam coated galvanized steel drain pan has 7 8 ODM copper outlet Stainless steel drai...

Страница 21: ...ip pan available for piping package condensate 4 Coil hand is field reversible left hand unit shown Unit Size Fan Qty A B C D E 06 1 14 356 20 508 23 1 8 587 34 864 6 7 8 175 08 1 19 483 25 635 28 1 8...

Страница 22: ...and ordinances 2 Optional bottom control enclosure with hinged cover replaces standard side mounted enclosure and includes 2 additional knockouts on bottom of unit on left side 3 Standard externally...

Страница 23: ...drip pan available for piping package condensate 4 Coil hand is field reversible left hand unit shown Unit Size Fan Qty A B C D E 06 1 14 356 20 508 23 1 8 587 34 864 16 406 08 1 19 483 25 635 28 1 8...

Страница 24: ...622 12 27 1 2 699 45 1 4 1149 34 864 31 1 2 800 14 32 1 2 826 50 1 4 1276 39 991 35 1 2 902 16 37 1 2 953 55 1 4 1403 44 1118 39 1 2 1008 18 42 1 2 1080 60 1 4 1530 46 1225 44 1 2 1130 20 46 1 2 1181...

Страница 25: ...12 62 1575 59 7 8 1599 32 814 31 7 8 811 60 1 8 x 36 1 8 1527 x918 14 67 1702 64 7 8 1646 36 916 35 7 8 912 65 1 8 x 36 1 8 1654 x 918 16 72 1829 69 7 8 1773 40 1017 39 7 8 1014 70 1 8 x 36 1 8 1781 x...

Страница 26: ...8 hw 4 7 8 16 hw 4 1 1 8 08 cw 4 7 8 16 cw 4 1 1 8 08 cw 6 7 8 16 cw 6 1 1 8 10 hw 1 5 8 18 hw 1 5 8 10 hw 2 5 8 18 hw 2 7 8 10 hw 3 7 8 18 hw 3 7 8 10 cw 3 7 8 18 cw 3 1 1 8 10 hw 4 7 8 18 hw 4 1 1 8...

Страница 27: ...IONS Install Duct work Fittings Grilles as Required Proper Supply Return Grille Type Size Used Control Outside Air for Freeze Protection Insulate All Duct work as Required ELECTRICAL CONNECTIONS Refer...

Страница 28: ...28 Installation Manual THH Redefine your comfort zone www titus hvac com THH HIGH PERFORMANCE HORIZONTAL FAN COIL UNITS Notes...

Страница 29: ...29 Installation Manual THH Redefine your comfort zone www titus hvac com Notes...

Страница 30: ...605 Shiloh Rd Plano TX 75074 ofc 972 212 4800 fax 972 212 4884 Redefine your comfort zone www titus hvac com...

Отзывы: