8. Commissioning
Check the riveting tool visually before
commencing any work
— For visible damages
— For oil leaks
Check the nose cap is tightened to the
house head and select the correct nose-
piece for the rivet being used
Test of the tool function without rivets
prior processing –20 times
(Tool operation)
9. Tool operation
—
After inspection before first use (com
-
missioning)
— Connect the tool to the air supply (6
– 7 bar)
— To avoid damage to the tool, caused
by exceeded air pressure, the integra-
ted safety valve will switch to release
air. In this case, adjust the air pressure
to the correct value
—
Check for correct assembly and fit of
the quick connectors – no air dischar-
ge is audible
— Press and hold the air suction trigger
(8)– the riveting tool starts soaking air
though the nosepiece.
— Insert the mandrel of the rivet in the
nosepiece (5) (the rivet will be held in
nosepiece by the air flow).
— Move the tool with rivet to the alloca-
ted riveting position.
— Press the trigger (7) – the riveting
tool performs the pulling movement
(pulling and tearing the mandrel)
— Release the trigger (7) after setting
the rivet and the pulling unit auto-
matically returns to its initial starting
position
— Hold the air suction trigger (8) during
the riveting cycle to eject the ripped
off mandrel into the mandrel collector
(2).
— Make sure, the mandrel is ejected
before the next riveting cycle.
— Release the air suction trigger (8),
to switch off the air suction flow or
continue with the next cycle.
Connecting the tool
with the air supply