25
Operating the riveting tool
Check function
Attention
Too narrow clearance can cause damage to material. If you
do not know the stroke setting, unscrew the adjustment
screw (6.1) for the automatic switching into the left-handed
rotation a few turns (ca. 5 mm). You thus make sure that
the rod does not strike the rear and the riveting tool is not
damaged.
• Connect the air supply to the riveting tool.
• Push the trigger (12) through and hold.
• Gently screw in the adjustment screw (6.1) as far as it can go: The
automatic switch over to left-handed rotation is now set.
• Release the trigger (12).
• Gently push down the trigger (12) (first level): The air motor is rotating in
a right-handed direction.
• Release the trigger (12): the air motor stops.
• Again press the trigger (12) down to the first level: The air motor rotates
in a right-handed direction.
• Push the trigger (12) right through and hold (second level): The mandrel
is pulled to the rear; the air motor stops.
• Release the trigger (12): the air motor rotates to the left; the mandrel
moves forward.
• Gently tap the trigger (12): The air motor stops.
• Push button (6.2): The air motor rotates towards the left.
• Gently tap the trigger (12): The air motor stops.
6.1
12
6.2
6.1
E
6.1