Page 26
For technical questions, please call 1-888-380-0318.
Item 64806
Sa
FE
ty
W
E
lding
t
ip
S
tig
/ Stick
control
S
Wir
E
M
aint
E
nanc
E
Stick Setup
connect cables
Electrode Holder
cable in positive Socket
ground clamp cable
in negative Socket
ground
clamp
Electrode
Holder
1. Plug Ground Clamp Cable into Negative Socket.
Twist clockwise all the way to lock in place.
2. Plug Electrode Holder Cable into Positive Socket.
Twist clockwise all the way to lock in place.
connect power cord
1. Turn the Power Switch off before
connecting Power Cord.
2.
iMportant: change the Voltage Switch
on the back of the Welder to the
voltage of the outlet you will use.
3. If using 120VAC, connect the included adapter to
the end of the Power Cord.
If using 240VAC, do not use the adapter.
4. Plug the Power Cord into a properly
grounded and rated receptacle that matches
the plug and selected voltage.
note:
The circuit must be equipped with
delayed action-type circuit breaker or fuses.
power
Switch
Voltage
Switch
240V to 120V Plug Adapter
Voltage switch and plug need to
be changed at the same time.