Version 2.01 TS132/TS142/TS152 QIG
M4-1-2 Flash
Press and hold button 3 for 2 seconds, there will be a .75 second
pulse from the Blue Re-arm wire. Press and hold button 4 for 2
seconds, there will be a .75 second output pulse from the Green /
Black Dis-arm wire.
M4-1-3 Flash
Press and hold button 3 for 2 seconds, there will be a 3.5 second
pulse from the Blue Re-arm wire. Press and hold button 4 for 2
seconds, there will be a 3.5 second output pulse from the Green /
Black Dis-arm wire.
M4-1-4 Flash
Wires operate as default Re-arm and Dis-arm outputs. (Default)
R
ED
/
WHITE AS AUXILIARY OUT
M4-3-1 Flash
Red / White Trunk release output will operate as a defrost output and
provide a .75 second pulse 30 seconds after the vehicle remote starts.
M4-3-2 Flash
Red / White Trunk release output will operate as a driver
¶
s priority
output and provide a .75 second pulse with a second press of the
Unlock button on the remote. This second button press must be
within 5 seconds of the first for the output to happen.
This output takes precedence over negative park light switchover in
program M2-2. In other words if this output is programmed as
driver
¶
s door priority, polarity will be negative and the park light
output will go back to positive. At this point an installer would have
to use a relay for negative park lights.
M4-3-3 Flash
Red / White Trunk release output operates with a 3.5 second output.
M4-3-4 Flash
Red / White Trunk release output operates with a .75 second
output