30
THE DRAIN LINE PLUMBING CONFIGURATION SHOULD INCLUDE ALL REQUIRED
SAFETY COMPONENTS TO PREVENT OVERFLOWS RESULTING FROM A POWER
FAILURE DURING REGENERATION.
MAINTENANCE & TROUBLESHOOTING
THE CONTROLLER MUST BE DEPRESSURIZED BEFORE REMOVING ANY QUICK
CONNECTION CLIPS OR THE VALVE ITSELF FOR SERVICING. THE CONNECTOR
SHOULD BE PUSHED TOWARD THE CONTROL VALVE WHILE REMOVING CLIPS.
Service Recommendations
Your Fleck 5810 valve is built for long term operation with limited maintenance. The seals
and spacers and piston assembly require periodic servicing or replacement, generally every
2 to 5 years. See Service Bulletin #5810-1 for instructions on this procedure.
THE METSORB TITANIUM DIOXIDE MEDIA SHOULD BE REPLACED IF CONTAMINANT
LEVELS FOUND DURING MONITORING TESTING EXCEED U.S. EPA OR HEALTH CANADA
GUIDELINES.
Inadequate backwash duration or flow rates could cause media clogging which could
require the replacement of the media to restore flow and pressure performance.
Troubleshooting
PROBLEM
CAUSE
CORRECTION
1. Valve fails to backwash
A. Electrical service to unit has
been interrupted.
B. Timer is defective.
A. Assure permanent electrical
service (check fuse, plug, pull
chain or switch).
B. Replace timer.
2. Loss of water pressure.
A. Contaminant build-up in feed
line.
A. Clean line to water filter.
B. Perform manual backwash.