6
* While the TITAN-Ox™ system is built to withstand pressures exceeding 90 PSI, if your water
pressure is greater than 70 PSI, we recommend that you have a certified plumber install a
pressure reducing valve ahead of the TITAN-Ox™ system.
** The system cannot be subjected to freezing conditions or severe damage to the system
and your property could occur.
*** pH correction is strongly recommended where pH levels are less than 6.5 to prevent
damage to your control valve and plumbing system, and to prevent leaching of metals from
copper and brass plumbing components and solder in your home. Contact your dealer for
recommendations.
IF YOUR TOTAL ARSENIC LEVEL IS GREATER THAN 60 PARTS PER BILLION (0.060 MG/L),
PLEASE CONTACT ONE OF OUR CERTIFIED WATER TECHNICIANS FOR SIZING
ASSISTANCE (PHONE TOLL FREE 1-866-376-2690). A LEAD/LAG CONFIGURATION OR
LARGER MEDIA VOLUME MAY BE REQUIRED FOR DESIRED TREATMENT.
TITAN-Ox™ Series Flow Rates & Backwash Requirements:
Model
Optimal
Service Flow
Rate* (GPM)
Maximum
Service Flow
Rate* (GPM)
Backwash Flow Rate
at 40F Water Temp
(GPM)
Backwash Flow Rate
at 70F Water Temp
(GPM)
TOx-5810XTR2-10-54
2.7
5.5
4.5
6
TOx-5810XTR2-12-52
3.9
7.9
7
8
TOx-5810XTR2-13-54
4.6
9.2
8
10
TOx-5810XTR2-14-65
5.3
10.7
9
12
CONFIRM THAT YOUR WATER CONDITIONS, SERVICE FLOW RATE NEEDS, AND
AVAILABLE BACKWASH FLOW RATES MEET THE ABOVE SPECIFICATIONS FOR THE
MODEL YOU ARE INSTALLING BEFORE COMMENCING THE INSTALLATION PROCESS.
IF IN DOUBT, CALL YOUR DEALER FOR ADVICE. INSTALLED UNITS CANNOT BE
RETURNED.