12. Release the hydraulic pressure from the cylinder and the center foot
will retract.
13. Install the dowel pin (7) in the hole on the side of the housing (8),
use a hammer if necessary. The dowel pin will ride in the slot on the side
of the piston (6), if everything is properly assembled.
14. Check the feet again to be sure they are still aligned. Check the
alignment of the cylinder in reference to the housing (this should have
been marked in disassembly). Insert the set screw (9) in the hole pro-
vided in the front of the housing (8). Tighten the set screw to the cylinder.
Do not tighten the set screw too tight, or future removal of the cylinder
may be diffi cult.
15. Pressurize and de-pressurize the cylinder to check that the tool is
operating properly.
Trouble Shooting
General Notes:
- Do not twist or bend hoses too sharply.
- Pay close attention to keeping all parts clean internally
and externally. (Dirt and foreign matter are the most
common causes of trouble in hydraulic systems)
- Make sure all quick couplers are always completely
coupled together.