4. Engage the screw using a pry bar and pull it out 1/2”. The dowel pin
should come out along with the screw.
5. Extend the cylinder to the maximum extension mark on the piston (6).
6. Pressurize the cylinder to 2,000 PSI or so.
7. Turn the sub-assembly counter-clockwise until it is completely un-
screwed and slides out easily. The sub-assembly consists of the adapter
(10), piston (5) and the center foot (7).
8. Release the pressure to retract the cylinder and disconnect the cylin-
der from the pump.
9. Loosen the set screw in the front of the housing with a 5/36” Allen
wrench. Remove the cylinder (11) by turning it counter-clockwise.
Assembly Instructions
1. Review the Parts List and verify that all the parts are available and in
good order.
2. Clean all the parts with a de-greasing solvent.
3. Screw the cylinder (11) all the way onto the housing (8).
4. Position the outside feet (2 and 3) against the bottom of the housing
(8). Be sure to place the feet, which are marked (L) and (R), on the ap-
propriate sides of the housing. The countersunk screw holes should be
facing out, and not against the bottom of the housing (8).
5. Insert the fl at head Allen screws (1) in the screw holes on the outside
feet, and tighten them with a 5/16" Allen wrench to 35-40 Ft lis.
6. Place the center foot (5) on top of the piston. The countersunk screw
holes will be facing up. See fi gure 7.